Vaisala WAC151 Скачать руководство пользователя страница 7

Cross Arm WAC151 

Technical Reference 

WAC151-T648en-1.1 

1996-09-25 

2. 

INSTALLATION 

Figure  WA35095  illustrates  mounting  of  the  WAC151  to  the  top  of  a  Ø  60 
mm pole mast, with the standard mounting clamp. For installation, follow the 
procedure below: 

1

 

Remove  the  four  screws  attaching  the  cover  of  the  WAC151  unit. 

 

Remove the cover. 

2

 

Enter the power and signal cables through the cable glands(s). For better 

 

protection  against  RF  interference,  follow  the  earthing  instructions  of 

the   cable shield in drawing WA35095. 

3

 

Do  the  wiring  to  the  screw  terminal  block  according  to  the  drawing 

 

WA35172.  Notice  that  the  factory  wiring  is  for  WAA151  &  WAV151 

 

sensors. If WAA251 is used with WAV151, 10 k

 NTC (delivered with 

 

the  WAA251)  must  be  used  instead  of  thermostat.  Tighten  the  output 

 

cable gland(s). 

4

 

Carefully reattach the enclosure cover with the four screws. 

5

 

Attach the unit to the top of a pole mast with the mounting clamp. 

Содержание WAC151

Страница 1: ......

Страница 2: ...CROSS ARM WAC151 Technical Reference WAC151 T648en 1 1 25 September 1996 Vaisala 1996...

Страница 3: ...y form or by any means electronic or mechanical including photocopying nor may its contents be communicated to a third party without prior written permission of the copyright holder The contents of in...

Страница 4: ...Cross Arm WAC151 WAC151 T648en 1 1 Technical Reference 1996 09 25 i Contents 1 INTRODUCTION 1 2 INSTALLATION 2 3 TECHNICAL DATA 3 4 APPENDICES DRAWINGS 4...

Страница 5: ...Cross Arm WAC151 Technical Reference WAC151 T648en 1 1 ii 1996 09 25 This page intentionally left blank...

Страница 6: ...able glands offering easy way for earthing different cables Typically three cable glands are in use two for sensor cables one for signal cables To ensure accurate wind speed measurement in extreme win...

Страница 7: ...cables through the cable glands s For better protection against RF interference follow the earthing instructions of the cable shield in drawing WA35095 3 Do the wiring to the screw terminal block acco...

Страница 8: ...m supports the WAA151 WAA251 and WAV151 sensors Material Cross Arm Al anodized Junction Box Al painted Weight 1 5 kg without sensors Electrical connections Cable entries Line cable entry through a gla...

Страница 9: ...ence WAC151 T648en 1 1 4 1996 09 25 4 APPENDICES DRAWINGS WA35095 WAC151 Cross Arm Assembly ZZ45037 Sensor Wind Vane Cable Assembly ZZ45036 Sensor Anemometer Cable Assembly WA35172 WAT11 Wind Sensor C...