Table 13
Explanation of Configuration Wizard Buttons
Button
Explanation
Radio Modem
Opens Radio Modem Configuration program
Dial-up
Opens optional Dial-up Manager
Silence MAWS/
Enable MAWS
Silences MAWS
Asks which radio channel to use and then
enables MAWS
Sensor Terminal
Opens Sensor Terminal application
M4 Services
Opens MIDAS IV Service Manager
M4 Diagnostics
Opens Diagnostics Monitor
Start M4
Starts MIDAS IV applications
Stop M4
Stops MIDAS IV applications
Apply
Accepts configuration changes
Cancel
Cancels configuration changes
Locations...
Opens METAR/SPECI Manager application
System Parameters Tab
From the System Parameters tab (see Figure 31 on page 57), you can
configure the parameters described in Table 14 below.
Table 14
Explanation of System Parameters tab
Item
Description
Configuration
Select your system configuration: 1 Basic station, 1 Enhancement station,
Basic and Basic stations, Enhancement and Basic stations, Enhancement
and Enhancement stations, or Fixed Station (mast installation).
Units
Select the units you want to use: SI or US
Station identifier
The unique ICAO identifier with 4 characters when the METAR message is
sent to AFTN. Otherwise, give the station ID, for example, airfield name.
Runway direction
Give the Runway direction in degrees, for example, 20
Magnetic correction
Give the difference between magnetic north and true north
Enable METAR
Check only if you want the system to generate METAR/SPECI messages
Enable AUTOMETAR
Check only if you want to enable automatic METAR/SPECI sending feature
Show AUTO text
Check only if you want the AUTO text to appear in the header of
METAR/SPECI message
METAR type
Select METAR/SPECI type: US or ICAO
METAR interval
Select METAR/SPECI sending interval in minutes: 30 or 60
METAR observation
time
Select METAR/SPECI editing start time: 00, 05, 10, 15, 20, 25, 30, 35, 40,
45, 50, or 55 minutes past the hour
METAR edit time
Select the desired METAR/SPECI editing time in minutes, for example 3.