Processing stage
API support
Parameter generation from (
I
,
Q
)
• Redefine how standard parameters (
dBZ
,
Velocity
,
Width
,
PHIDP
, and so on) are
computed from the incoming (
I
,
Q
) time
series.
• Create new parameter types.
The standard scientific algorithms are not public. Many RVP10 library routines are also
documented and can be called by user code, but the source to these routines is not generally
released. Development tools must be purchased separately.
3.3.6 Installing the RVP10SRV server computer
The RVP10SRV server computer has two power supplies.
Disconnect power from both power supplies when powering down or
servicing the unit.
WARNING!
1. Mount the RVP10SRV server chassis in an equipment rack on rack slides.
2. Use the fiber optic cable to connect IFDR10 to the RVP10SRV server chassis.
Clean the connectors carefully with appropriate tools. If the connectors are not properly
cleaned, the data quality may suffer.
3. Connect the power cables.
The device includes dual-redundant power supplies, with two line cords.
3.3.6.1 Powering up RVP10SRV
1. Power-up and boot IFDR10.
If IFDR10 is not powered-up and booted, the
rvp10
process cannot start on RVP10SRV.
2. Start or reset RVP10SRV.
The host Linux PC goes through an automated boot process that ultimately starts the
RVP10 application.
3. While RVP10SRV runs extensive internal diagnostics, if no display is connected yet, you
can connect a display to view any error messages or monitor the startup log
in
/var/log/irisrda/rvp10.log
.
Chapter 3 – Hardware description
RESTRICTED
19
Содержание RVP10