User's Guide ______________________________________________________________________
186 _________________________________________________________________ M210667EN-C
Table 35
Default Factory Parameter Settings
Parameter Default
Setting
Message type
1
Message interval
10
Message port
Data
Unit_id -
Name -
Header LT
Data_port baud
9600
Data_port mode
RS-232
Data_port parity
8N1
Module modem
Off
Maintenance_port baud
9600
Port_timeout 10
Terminal_lines 24
Contamination_compensation bl_sensor
On
LM Off
PWD On
Hood_heaters bl_sensor
On
Dew_heaters bl_sensor
On
Message_frame On
+12VOUT Off
Blow on WMO
0
PWD pitch
1.000
Internal Filter
1.00
Heat on Battery
Yes
Base Length
30 meters
MOR Range
10 to 10 000 meters
BL Range
1 to 100 000 cd/sqm
External Sensors (Optional)
Background Luminance Sensor LM21
The
SET LM ON
configuration command is used to add the LM21
sensor output into the LT31 system and the data messages. With this
command, the interface unit CPU starts polling the LM21 sensor via the
internal RS-485 sensor interface.
RVR System Test Commands
LT31 can be set to a simulation mode which includes transmitting fixed,
user defined or sequenced visibility and status information. This function
is intended for system testing purposes. The normal visibility detection
mode takes effect after a reset. The simulation mode can also be stopped
with the
SIMULATE OFF
command in the advanced level.