User's Guide _______________________________________________________________________
86
______________________________________________________ M210296en-A
SIGNAL
0.39 OFFSET
126.83 DRIFT
0.14
REC. BACKSCATTER
1281 CHANGE
-1
TR. BACKSCATTER
10.3 CHANGE
0.1
TE
2.7
VBB
19.4
VH
0.6
LEDI
5.6
P15
15.1
M15
-15.0 BGND
-0.1
AMBL
0.1 DUTY
1.6
DRI21 MEASUREMENTS
TS
1.8 DRD INST
811 DRY
915.6
HARDWARE :
OK
An asterisk (*) before a value indicates an exceeded limit.
In the end, there are verbal comments on the combined errors
detected. These comments can be one or many of the following listed
in Table 22 below.
Table 22
Hardware Error Texts
Error text
Description
BACKSCATTER HIGH
The receiver or transmitter contamination signal
has increased more than the ALARM limit given
in the configuration.
TRANSMITTER ERROR
The LEDI signal is more than 7 V or less than
-8 V.
+15 V POWER ERROR
The receiver/transmitter power is less than 14
V
or more than 16 V.
OFFSET ERROR
The offset frequency is zero (cable is
disconnected).
SIGNAL ERROR
The signal frequency is less than 50 % of the
offset frequency.
RECEIVER ERROR
Too low signal detected in the receiver
backscatter measurement.
DATA RAM ERROR
The error is in RAM read/write check.
EEPROM ERROR
This is an EEPROM checksum error.
The hardware warning texts are listed in Table 23 below.
Table 23
Hardware Warning Texts
Warning text
Description
BACKSCATTER
INCREASED
The receiver or transmitter contamination signal
has increased more than the WARNING limit
selected in the configuration.
TRANSMITTER
INTENSITY LOW
The LEDI signal is less than
-3
V
.
RECEIVER
SATURATED
The AMBL signal is less than -9
V
.
OFFSET DRIFTED
The offset has drifted more than
±
5 Hz from the
reference value.
LENS HEATER OFF
No current flowing to lens heaters.
DRI21 NOT
The DRI21 board cannot be detected.