Vaillant VWZ AI VWL X/2 A West Скачать руководство пользователя страница 5

Electrical installation 5

0020151756_01 Heat pump control module Installation instructions

5

4.2

Installing the product

PE  N    L

230 V~

+   -

Bus

VF1

SP1

PE  N    L

230 V~

AF       DCF

DCF/AF

ME

EVU

PE  N    L

MA1

PE  N    L

MA2

PE  N Auf Zu

UV1

PE  N   1    2

ZH

2   1

2   1

2   1

2   1

1

1.

Mount the product and the supplied installation access-
ory on the wall. Use the fixing points

(1)

for this.

2.

Connect the product. (

Page 6)

4.3

Closing the casing

1.

Insert the casing cover at the top into the hinges.

2.

Fold down the casing cover.

3.

Screw the bolt into the underside of the casing.

4.4

Installing the VR 10 standard sensor

Note

You can use the

VR 10

as a cylinder temperature

sensor (for example, as an immersion sensor
in a cylinder dry pocket), as a flow temperature
sensor (for example, in the low loss header) or
as a surface mount sensor. We recommend that
the pipe with the sensor be insulated to ensure
optimum temperature recording.

If you use the

VR 10

as a surface mount sensor, secure

the

VR 10

to a return/flow pipe using the enclosed strap.

4.5

Installing the external temperature sensor

Installing the external temperature sensor

1

AF          DCF

DCF/AF

2

1 Connection cable to the

VRC 693 external temper-
ature sensor

2 Connector in the product

Install the external temperature sensor in accordance
with its enclosed installation manual.

5

Electrical installation

Danger!
Risk of death from live connections!

There is a risk of death from electric shock

when working on the open product and in the

electronics box of the heat pump.

Before working on the product and in the

heat pump's electronics box, switch off the

power supply.

Secure the power supply against being

switched on again.

Danger!
Risk of damage caused by incorrect in-

stallation.

Connecting wires that have been stripped

too far may cause short circuits and damage

the electronics if a strand accidentally comes

loose.

Only strip the outer sheathing of flexible

cables to a maximum of 2.5 cm to prevent

short circuits.

Lay the lines correctly.

Use strain reliefs.

Содержание VWZ AI VWL X/2 A West

Страница 1: ...on instructions Heat pump control module VWZ AI VWL X 2 A UK Installation instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Telefon 021 91 18 0 Telefax 021 91 18 28 10 info vaillant de www vaillant de ...

Страница 2: ... 2 3 Applicability of the instructions 4 3 Product overview 4 3 1 Overview of functional elements 4 3 2 Connecting the mains connection line to the eBUS in the system 4 3 3 Scope of delivery 4 4 Installation 4 4 1 Opening the casing 4 4 2 Installing the product 5 4 3 Closing the casing 5 4 4 Installing the VR 10 standard sensor 5 4 5 Installing the external temperature sensor 5 5 Electrical instal...

Страница 3: ... x 1 5 Do not use any flexible cables for 230 V lines Type of line Min cross section Cross section of 230 V supply line pump or mixer mains cable 1 5 mm Cross section of eBUS line extra low voltage 0 75 mm Cross section of sensor line extra low voltage 0 75 mm Type of line Max length Sensor lines 50 m Bus lines 300 m 1 3 2 Regulations directives laws standards All wiring must be in accordance with...

Страница 4: ...39944 3 Product overview 3 1 Overview of functional elements 1 2 3 1 LED 2 Diagnostic socket for later use 3 Identification plate 3 2 Connecting the mains connection line to the eBUS in the system Connection diagram 230 V 2 1 4 5 3 1 Heat pump 2 Controller 3 VWZ AI VWL X 2 A 4 230 V mains connection line on site 5 eBUS line The product is connected to the power supply on site You can branch the eB...

Страница 5: ...ing If you use the VR 10 as a surface mount sensor secure the VR 10 to a return flow pipe using the enclosed strap 4 5 Installing the external temperature sensor Installing the external temperature sensor 1 AF DCF DCF AF 2 1 Connection cable to the VRC 693 external temper ature sensor 2 Connector in the product Install the external temperature sensor in accordance with its enclosed installation ma...

Страница 6: ...e in the position for cylinder charging 230 V is output to the Closed contact Note The EVU contact is used to connect a block ing signal can be configured on the control ler Contact open Operation permitted Contact closed Operation blocked 3 Secure all lines in the product using the enclosed strain reliefs 4 Close the casing Page 5 6 Start up 6 1 Starting up the product 1 Ensure that the casing is...

Страница 7: ......

Страница 8: ...lephone 08 45 602 29 22 Vaillant Service Solutions 080 70 606 07 77 info vaillant co uk www vaillant co uk Vaillant GmbH 2013 These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent 2703479_rev 1 ...

Отзывы: