Appendix
0020239015_05 ecoTEC plus Installation and maintenance instructions
27
#
Maintenance work
Interval
25
Check and, if required, replace the insulating mat in the burner area
If required, at least every
5 years
26
Installing the gas-air mixture unit
If required, at least every
5 years
25
27
Reassemble the product
After each time maintenance
work is carried out
28
Open the service valves, carry out the required leak-tightness test
Annually
29
Fill the product/heating installation to the filling pressure specified for the
system
Annually
30
Connect the product to the electrical installation
Annually
31
Run the test operation on the product/heating installation including hot
water generation (if available) and, if required, purge the product/heating
installation
Annually
32
Record all of the analysis results in the Benchmark service record in
these instructions
Annually
B
Installer level
–
Overview
Setting level
Values
Unit
Increment, select, explanation
Default
setting
Min.
Max.
Installer level
→
Enter code
00
99
–
1 (competent person code 17)
–
Installer level
→
List of faults
→
F.XX - F.XX
¹
Current value
–
–
–
Installer level
→
Test programs
→
Gas type check
Current value
–
Liquid gas, natural gas
–
Installer level
→
Test programs
→
Check programs
→
P.00 Purging
–
–
–
Yes, No
–
P.01 Maximum load
–
–
–
Yes, No
–
P.02 Minimum load
–
–
–
Yes, No
–
P.06 Filling mode
–
–
–
Yes, No
–
Installer level
→
Test programs
→
Function menu
→
T.02 3-way valve
–
–
–
On, Off
–
T.03 Fan
–
–
–
On, Off
–
T.04 Cyl. charging pump
–
–
–
On, Off
–
T.05 Circulation pump
–
–
–
On, Off
–
T.06 External pump
–
–
–
On, Off
–
T.08 Burner
–
–
–
On, Off
–
Installer level
→
Test programs
→
Electronics self-test
→
Self-test
–
–
–
Yes, No
–
Installer level
→
Appliance config.
→
Language
–
–
–
Deutsch, English, Français, Italiano, Dansk,
Nederlands, Castellano, Türkce, Magyar,
Pусский, Українськa, Svenska, Norsk, Pol-
ski, Čeština, Hrvatski, Slovenčina, Română,
Slovenščina, Português, Srpski
English
¹