15
Operating instructions VRC 430f 0020042470_01
Screen
Title
screen
adjustable
operating values
(only display = A)
Remarks
Unit
Min.
value
Max.
value
Step dis-
tance
Preset value
10
Hot water
parameters
Hot water target set
temperature
Target temperature for
water heating
°C
35
70
1,0
60
14
Changing
the name
Heating circuit 1
Any name having up to 8
characters can be entered
Heating cir-
cuit 1
Hot water
Hot water
15
Enable
code layer
Code number
Access to the level for the
installer only by entering
the saved code number
1000
Table 4.4 Screens in the Operator level (continued)
4.7 Edit
screens
(examples)
4.7.1 Entering
timer
programmes
(example for heating circuit)
Using the time programmes you can allocate up to three
time windows per day, or block of days (e.g. Mo - Fr). In
these time windows, the heating system maintains the
room temperature that you have selected, the so-called
comfort temperature. Outside the time windows, the
room temperature is set back.
h
Note!
If you set the timer windows carefully to suit
your lifestyle, you will save energy without los-
ing any heating comfort.
The next section describes how to set the timer win-
dows using heating circuit 1 as an example. You can de-
fine time windows in a similar way for hot water and for
a circulation pump .
Turn the left-hand dial until screen 2 (HC1 time
programme) is displayed.
HC 1
Time programme
2
Mo
1
06 : 00 -
10 : 40
21.5 °C
2
:
-
:
3
:
-
:
> Select day/block
Fig. 4.13 Screen 2 (example)
Turn the right-hand dial until the cursor is
positioned in front of the day or block of days input
field.
Click the right-hand dial.
The field is highlighted.
Select the required day or block of days by turning
the right-hand dial. The following options are availa-
ble:
– Mo, Tu, ... etc.
– Mo - Fr (Block)
– Sa - Su (Block)
– Mo - Su (Block)
Confirm the selection by clicking with the right-hand
dial.
1, 2 and 3 indicate the "time windows" which you can
programme for the selected weekday or block of days.
Within the time window (e.g. from 06:00 to 10:40) the
heating is on to achieve the associated comfort temper-
ature.
Turn the right-hand dial until the cursor is
positioned in front of the input field for the starting
time of time window 1.
Click the right-hand dial.
The field is highlighted.
Set the start time by turning the right-hand dial.
Each step of the dial changes the time by 10 minutes.
Once the desired starting time is displayed, confirm
by clicking the right-hand dial.
Operation 4