Appendix
16
Operating and installation instructions 0020253110_01
Setting level
Values
Unit
Increment, select
Default
setting
Min.
Max.
Day temp. heating
5
30
℃
0.5
20
Day temp. cooling
15
30
℃
0.5
24
Set-back temp. heat.
5
30
℃
0.5
15
Time programmes
→
ZONE1
: Heating
→
Individual days and
blocks
Monday
,
Tues-
day
,
Wednesday
,
Thursday
,
Friday
,
Saturday
,
Sunday
and
Monday - Fri-
day
,
Saturday -
Sunday
,
Monday -
Sunday
Mo - Fr:
06:00-
22:00
Sa: 07:30-
23:30
Su: 07:30-
22:00
Period 1:
Start
–
End
Period 2:
Start
–
End
Period 3:
Start
–
End
00:00
24:00
h:min
00:10
Time programmes
→
ZONE1
: Cooling
→
Individual days and
blocks
Monday
,
Tues-
day
,
Wednesday
,
Thursday
,
Friday
,
Saturday
,
Sunday
and
Monday - Fri-
day
,
Saturday -
Sunday
,
Monday -
Sunday
Mo - Fr:
06:00-
22:00
Sa: 07:30-
23:30
Su: 07:30-
22:00
Period 1:
Start
–
End
Period 2:
Start
–
End
Period 3:
Start
–
End
00:00
24:00
h:min
00:10
Days away from home scheduling
→
Start
01.01.01
31.12.99
dd.mm.yy Day.Month.Year
01.01.14
End
01.01.01
31.12.99
dd.mm.yy Day.Month.Year
01.01.14
Temperature
5
30
℃
1
15
Days at home scheduling
→
Start
01.01.01
31.12.99
dd.mm.yy Day.Month.Year
01.01.14
End
01.01.01
31.12.99
dd.mm.yy Day.Month.Year
01.01.14
Basic settings
→
Language
→
Selectable language
English
Basic settings
→
Display
→
Display contrast
1
15
1
9