background image

6

Operating instructions for VED electric instantaneous water heater 0020149586_00

4 Energy-saving 

tips

You can help to save energy by following the tips and 
advice below:

Appropriate hot water temperature

The water should only be heated up to the extent that is 
necessary for use. Any further heating will result in 
unnecessary energy consumption. For you, this means 
that you should:

 

>

Set your VED to stage I in normal operating mode.

 

>

Briefly set the output selector to stage II in special 
cases where you need more hot water than stage I is 
able to provide. After using the hot water, remember 
to set the output selector back to stage I.

Detecting and rectifying faults

e

 

Danger!
Risk of death from electric shock.

Live lines and connections may cause a 
potentially lethal electric shock.

 

>

Do not attempt to repair the unit yourself 
under any circumstances.

 

>

Under no circumstances should the unit 
cladding be removed.

 

>

If the unit ever malfunctions, inform an 
approved heating specialist company 
immediately.

6 Care

There is no need to care for your Vaillant VED electric 
instantaneous water heater because all internal parts 
are protected against dirt and moisture. You can clean 
the exterior of the unit with a damp cloth and a little 
soap.

i

  Do not use any abrasive scouring or cleaning 

agents when cleaning the unit cladding.

Maintenance, guarantee and 
customer service

The permanent operational readiness, safety, reliability 
and long service life of your electronic VED electric 
instantaneous water heater require annual inspections 
and maintenance work to be carried out by a competent 
person.  

a

 Danger!

Risk of injury and material damage due 
to incorrect maintenance and repairs.

If you fail to carry out maintenance, or if 
you carry this out incorrectly, this may 
adversely affect the operating reliability of 
the unit.

 

>

Never attempt to perform maintenance 
or repairs on your 

VED

 

electric instanta-

neous water heater

 by yourself. 

 

>

You must employ an approved heating spe-
cialist company to complete such work. We 
recommend making a maintenance agree-
ment.

b

 Caution.

Possible material damage to the unit.

A lack of maintenance can affect the func-
tional safety of the VED. E.g. unit defects 
caused by limescale formation. In areas of 
hard water (more than 14 °dH = 2.5 
CaCO

3

 mmol/l) or very hard water (more than 

20 °dH = 3.6 CaCO

3

 mmol/l), a significantly 

more frequent maintenance interval may be 
required.

 

>

Have your VED inspected at least every 
3 years by a competent person.

 

>

If you live in an area with very hard water, 
Vaillant recommends that you have the 
maintenance service carried out once a 
year by a competent person.

Recycling and disposal

 

 If your Vaillant unit is labelled with this symbol, it 
does not belong with your household waste at the 
end of its useful life. 

 

>

Instead, take the unit to a collection point for recycling 
electrical and electronic devices.

For more information on where to take your used electrical 
or electronic devices, contact your town or district authori-
ties, waste disposal company, or the competent person who 
installed the unit.

4 Energy-saving tips, 5 Detecting and rectifying faults, 6 Care 
7 Maintenance, guarantee and customer service 8 Recycling and disposal

Содержание VED

Страница 1: ...Operating and installation instructions EXP VED ...

Страница 2: ......

Страница 3: ...For the operator Instructions for use VED Electric instantaneous water heater ...

Страница 4: ...ents 3 1 3 Applicability of the instructions 3 1 4 Identification plate 3 1 5 CE label 3 2 Safety 4 2 1 Classification of action related warnings 4 2 2 Intended use 4 2 3 General safety information 4 3 Functions and operation 5 4 Energy saving tips 6 5 Detecting and rectifying faults 6 6 Care 6 7 Maintenance guarantee and customer service 6 8 Recycling and disposal 6 ...

Страница 5: ...ntification plate The unit s article number is part of the serial number To find out the serial and article numbers refer to the iden tification plate The identification plate can be found to the right next to the operator control panel under the cover Vaillant GmbH Remscheid Germany Serial No VED H 18 7 21093500200752100006000000N3 18 kW 400 V 3 50Hz 1MPa 10bar p 15 900 Ohm cm IP 25 Observe opera...

Страница 6: ...e is also deemed to be improper The manu facturer supplier is not liable for any damage resulting from such use In this case the user alone bears the risk Intended use includes the following observance of the accompanying operating instal lation and maintenance instructions for the Vaillant product and any other parts and components of the system compliance with all inspection and maintenance cond...

Страница 7: ... heating specialist company Do not carry out any repairs yourself Do not open the unit cover under any circumstances 3 Functions and operation If you turn on the hot water at a draw off point mixer or separate tap your VED will automatically warm up the drinking water a Danger Risk of being scalded by hot water The water temperature at the draw off points can reach 60 C When using a VED electric i...

Страница 8: ...us water heater require annual inspections and maintenance work to be carried out by a competent person a Danger Risk of injury and material damage due to incorrect maintenance and repairs If you fail to carry out maintenance or if you carry this out incorrectly this may adversely affect the operating reliability of the unit Never attempt to perform maintenance or repairs on your VED electric inst...

Страница 9: ...VED Electric instantaneous water heater For the competent person Installation instructions ...

Страница 10: ...ional description 6 3 1 Overview 6 3 2 Function 6 4 Installation 6 4 1 Scope of delivery 6 4 2 Installation site 7 4 3 Required minimum clearances 7 4 4 Mounting the unit to the wall 8 4 5 Connecting the hot and cold water 10 4 6 Connecting the unit to the electricity supply 12 5 Starting up decommissioning 13 5 1 Purging the unit 13 5 2 Fitting the unit cladding 13 5 3 Checking the system s funct...

Страница 11: ...nd all other appli cable documents and if necessary any required tools to the system operator The system operator should retain these instructions and tools so that they are available when required 1 4 Applicability of the instructions These instructions apply for the following only Type designation Article number VED H 12 7 0010007731 VED H 18 7 0010007732 VED H 21 7 0010007733 VED H 24 7 0010007...

Страница 12: ... for their safety or have been instructed by him her about how to use the unit Children must be supervised to ensure that they do not play with the unit The Vaillant VED electric instantaneous water heater must only be used to heat up drinking water The Vaillant VED electric instantaneous water heaters are suitable for use only in an enclosed frost free room in a domes tic environment The Vaillant...

Страница 13: ...ric instantaneous water heater must only be used to heat up drinking water This potable water must meet the specific German or Austrian legal requirements for quality Otherwise it is not possible to rule out the risk of corrosion inside the unit Material damage due to improper use and or unsuitable tools Improper use and or the use of unsuitable tools may result in material damage e g water leaks ...

Страница 14: ... unit is listed in the Technical Data table in section 11 4 Installation a Risk of death Risk of death due to improper installation All work involved in the installation set up maintenance and repair of the VED electric instantaneous water heater must only be car ried out by a recognised competent person who also assumes the responsibility for installing the unit properly and commissioning it for ...

Страница 15: ...of operation for a relatively long period of time in an unheated room in cold weather the water in the unit and pipes may freeze This results in damage to the unit Install the unit in a permanently frost free room i The VED electric instantaneous water heater meets the current safety regulations for pro tected zone 1 and can therefore also be installed above the bath or in a shower area Wherever p...

Страница 16: ... Output selector 4 Hot water connection R 1 2 5 Cold water connection R 1 2 6 Lower anti spray water sleeve R Outside thread R 1 2 390 322 85 85 1 1 2 3 Fig 4 4 Connection dimensions Key 1 Installation plate 2 Cold water connection 3 Hot water connection 4 4 2 Removing the unit cladding 1 3 4 2 Fig 4 5 Removing the unit cladding Grip the two straps 1 on the panel 2 Splay the two straps pull them a...

Страница 17: ...ic shock due to water penetration if the anti spray water sleeve is completely cut away The anti spray water sleeve should prevent water penetrating the unit along the length of the mains connection cable If the anti spray water sleeve is completely cut away water can very easily penetrate and damage the unit and in the worst case scenario can cause a potentially lethal electric shock Never cut of...

Страница 18: ...of steel copper or plastic It is important to check with the manufacturer that pipes made of plastic can be used with temperatures of 65 C in normal operat ing mode In addition plastic pipes must be suitable for a significantly higher load in the short term An expansion relief valve on the cold water pipe is not required To simplify fitting the water connection the bottom section of the unit can b...

Страница 19: ...er s specifications When using plastic pipes ensure that they conform with DIN 16893 and DIN 16892 check manufacturer s specifications 1 2 3 4 5 6 7 Fig 4 9 Water connections Put hemp on the two double nipples 2 and 6 and use the connections to screw the double nipples to the wall 1 and 7 Insert the seals 3 in the cap nuts of the cold 4 and hot water connections 5 Screw the cold water connection p...

Страница 20: ...on of the unit but the electricity line must be fed through the lower anti spray water sleeve 4 6 1 Electrical connection from above The electricity line is fed through the upper anti spray water sleeve 2 Figure 4 7 explains how the anti spray water sleeve must be prepared Connect the individual conductors to L1 L2 and L3 and the protective earth to the mains connection terminal 1 in fig 4 10 3 1 ...

Страница 21: ...inadvertently to any of the supply lines and connections while you are working on the unit To start up the unit proceed as follows De energise the unit Open the cold water stop valve Close and open the hot water draw off valve several times The unit will then be purged In normal operat ing mode the unit will not need to be purged again Fig 5 1 Safety switch Push the safety switch 1 in as shown in ...

Страница 22: ...ter Above a water temperature of 43 C there is a risk of scalding When setting the output regulator to level II temperatures can reach up to 60 C Inform the operator that there is a risk of scalding above a water temperature of 43 C Recommend to the operator that in normal operating mode the output selector is set to level I to avoid scalding You must inform the operator of the unit about the han ...

Страница 23: ... supplied with the L1 L2 and L3 mains voltage Check the protective devices De energise the unit and open the unit cladding Check all the connection line connectors Resistance is outside the range of 200 ohm 2 Check the electrical func tion of the heating ele ment Measure the resistance value between the connections 1 and 4 on the elec tronics The resistance must be 200 ohm Water flow not adequate ...

Страница 24: ... must be replaced more often At the same time the water fil ter has a sealing function Carry out the following actions Replace the water filter in the cold water flow Check for deposits in the hot water pipe between the heating block and the hot water connection When re assembling the unit insert a new flat seal into the hot water connection Check whether the unit needs to be de scaled and do so i...

Страница 25: ...0 Outlet temperatures at 10 C for output selector level II Partial load C 40 Full load C 50 Outlet temperatures at 10 C for output selector level I Partial load C 30 Full load C 40 Measuring record for output selector level II Partial load kW 5 2 6 0 7 8 9 0 9 1 10 5 10 4 12 0 11 6 13 5 Full load T of 37 K kW 12 10 3 18 15 5 18 1 21 0 20 7 24 0 23 3 27 0 Measuring record for output selector level ...

Страница 26: ......

Страница 27: ......

Страница 28: ...0020149586_00 EXPen 072012 Subject to change Manufacturer ...

Отзывы: