VAI6-WN-U_EN - 10/13 - Vaillant
- 18 -
OPERATING INSTRUCTIONS
7.7.5
Temp function
Fig. 7.20 TEMP function selection.
Legend
1 TEMP button
2 TEMP indicator
This function displays the indoor setting temperature and
indoor ambient temperature on the Indoor Unit display.
Pressing the TEMP button will display:
Set temperature
Indoor ambient temperature
Outdoor ambient temperature
(Not available for this model)
1
2
3
4
5
6
7.8
Indicators of the Indoor unit
Fig. 7.21 Overview of the display in the indoor unit.
Legend
1 HEATING indicator
2 COOLING indicator
3 TEMPERATURE indicator
4 ON-OFF indicator
5 DEFROST indicator
6 Infra-red signal receiver
7.9
Emergency operation
Only use this function when the remote controller is broken
or has been mislaid.
In order to activate:
•
Press the emergency operation switch.
•
A beeping noise is heard which indicates that the function
has been put into operation.
Fig 7.22 Emergency operation/operation test switch.
Operating sequence:
• With the first press of the button, the unit enters into Auto
mode.
•
With the second press of the button, the unit switches off.
i
NOTE:
During Emergency Operation, the unit operates in
AUTO mode by default.
1
2
Содержание VAI 6-065 WN
Страница 2: ......
Страница 25: ......
Страница 26: ......
Страница 49: ......
Страница 50: ......
Страница 73: ......
Страница 74: ......
Страница 75: ...Manuale d uso Per l utente IT Manuale d uso VAI 6 025 WN VAI 6 035 WN VAI 6 050 WN VAI 6 065 WN Unit A Parete...
Страница 97: ......
Страница 98: ......
Страница 121: ......
Страница 122: ......