background image

Notes on the documentation 2

0020221297_05 uniSTOR Installation and maintenance instructions

5

2

Notes on the documentation

2.1

Observing other applicable documents

Always observe all the operating and installation instruc-
tions included with the system components.

2.2

Storing documents

Pass these instructions and all other applicable docu-
ments on to the end user.

2.3

Validity of the instructions

These instructions apply only to:

Product article number

VIH GB 120/3 BES

0010019215

VIH GB 150/3 BES

0010019216

VIH GB 180/3 BES

0010019217

VIH GB 200/3 BES

0010019218

VIH GB 250/3 BES

0010019219

VIH GB 300/3 BES

0010019220

2.4

Benchmark

Vaillant is a licensed member of the Benchmark Scheme.

Benchmark places responsibilities on both manufacturers
and installers. The purpose is to ensure that customers are
provided with the correct equipment for their needs, that it is
installed, commissioned and serviced in accordance with the
manufacturer’s instructions by a competent person approved
at the time by the Health and Safety Executive and that it
meets the requirements of the appropriate Building Regu-
lations. The Benchmark Checklist can be used to demon-
strate compliance with Building Regulations and should be
provided to the customer for future reference.

Installers are required to carry out installation, commission-
ing and servicing work in accordance with the Benchmark
Code of Practice which is available from the Heating and
Hotwater Industry Council who manage and promote the
Scheme.

Benchmark is managed and promoted by the Heating and
Hotwater Industry Council.

For more information visit www.centralheating.co.uk

3

Product description

3.1

Serial number

1

You can find the serial number on the data plate

(1)

, which is

located on the cylinder below the electronics box.

3.2

Information on the identification plate

The identification plate is attached to the product at the fact-
ory.

The identification plate keeps record of the country in which
the product is to be installed.

This product meets the requirements of standard EN
12897:2006.

3.3

CE marking

The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the declaration of conformity.

The declaration of conformity can be viewed at the manufac-
turer's site.

Содержание uniSTOR VIH GB 3 BES Series

Страница 1: ...llation and maintenance instructions uniSTOR VIH GB 3 BES GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaillan...

Страница 2: ...ensions 7 5 Installation 8 5 1 Setting up the unit horizontally 8 5 2 Hydraulic connection 8 5 3 Electrical installation 11 6 Start up 13 6 1 Setting the immersion heater thermostat 13 6 2 Cold water...

Страница 3: ...tenance instructions for the product and any other system com ponents installing and setting up the product in ac cordance with the product and system ap proval compliance with all inspection and main...

Страница 4: ...rrect tool 1 4 5 Risk of material damage caused by frost Do not install the product in rooms prone to frost 1 4 6 Risk of injury due to the heavy weight of the product Make sure that the product is tr...

Страница 5: ...that it meets the requirements of the appropriate Building Regu lations The Benchmark Checklist can be used to demon strate compliance with Building Regulations and should be provided to the customer...

Страница 6: ...tion area Select a sensible installation site and take into consideration the routing of the pipework system Install the cylinder as close as possible to the heat generator in order to minimise heat l...

Страница 7: ...ity Description 1 1 Enclosed documentation 2 1 Tundish with retainer 3 1 2 way motorised valve 4 1 Safety group 5 1 Expansion vessel 6 1 Bag with accessories 7 1 Domestic hot water cylinder and tempe...

Страница 8: ...at the dis cretion of the installer install a WRAS ap proved automatic air vent on the hot water outlet at the highest point 4 5 7 6 9 8 10 1 2 3 11 1 Heat generator heating return 2 Heat generator he...

Страница 9: ...0 3 MPa 3 0 bar 150 800 mm 0 3 MPa 3 0 bar Size of the cylinder Length of the pipe that has a diameter of 22 mm Pre charge pres sure of the expan sion vessel 180 800 mm 0 3 MPa 3 0 bar 210 900 mm 0 3...

Страница 10: ...ef valve G1 2 is 18 m The resistance of the four 28 mm elbows which are each 1 0 m in length must be subtracted from this i e a total of 4 0 m The maximum per mitted length is accordingly 14 m As the...

Страница 11: ...supply Secure the power supply against being switched back on Caution Risk of material damage by drilling through the product The product may be damaged by drilling work Do not drill through the produ...

Страница 12: ...andards 3 Use heat resistant cables for the immersion heater con nection Diameter of the cable 1 5 mm 4 Connect the thermal cut out to the mains power supply using a double pole disconnector with a co...

Страница 13: ...it 1 Connect the thermostat for the primary circuit and the thermal cut out Diameter of the cable 1 5 mm Condition S plan 70 60 50 40 70 60 50 40 1 3 2 4 1 3 2 4 L N 2 1 3 2 2 4 4 1 8 L 8L 8L SL Conne...

Страница 14: ...for the heat gener ator 3 Move the lever to AUTO 4 Remove the cover for the electrics 5 Set the product s thermostat and the immersion heater s thermostat Setting the thermostats 60 6 Start up the hea...

Страница 15: ...ressure of the expansion vessel 1 Drain the product Page 15 2 Measure the pre charge pressure of the expansion ves sel at the vessel valve Condition Pressure 0 3 MPa 0 3 bar Top up the expansion vesse...

Страница 16: ...1 Set the expansion vessel 2 Interrupt the power supply of the product and heat generator check the thermal cut outs and replace these if you find any defects B Inspection and maintenance work Overvi...

Страница 17: ...r and domestic hot water 148 5 kg 183 6 kg 218 6 kg 240 4 kg 297 2 kg 342 7 kg Technical data Hydraulic connection VIH GB 120 3 BES VIH GB 150 3 BES VIH GB 180 3 BES VIH GB 200 3 BES VIH GB 250 3 BES...

Страница 18: ...ntenance instructions uniSTOR 0020221297_05 VIH GB 120 3 BES VIH GB 150 3 BES VIH GB 180 3 BES VIH GB 200 3 BES VIH GB 250 3 BES VIH GB 300 3 BES Propellant for insulating material GWP 5 GWP 5 GWP 5 G...

Страница 19: ...Appendix 0020221297_05 uniSTOR Installation and maintenance instructions 19 D Commissioning Checklist...

Страница 20: ...UROV KDYH EHHQ WWHG LQ FRPSOLDQFH ZLWK 3DUW RI WKH XLOGLQJ 5HJXODWLRQV Yes Type of control system if applicable Y Plan S Plan Other Is the cylinder solar or other renewable compatible Yes No What is t...

Страница 21: ...Date Engineer name Company name Telephone No Comments Signature SERVICE 05 Date Engineer name Company name Telephone No Comments Signature SERVICE 07 Date Engineer name Company name Telephone No Comme...

Страница 22: ...e 9 Documents 5 Drain valve 9 Draining the product 15 E Electricity 3 F Filling and purging the heating circuit 14 Filling and purging the product 14 Frost 4 H Handing over to the end user 14 I Identi...

Страница 23: ......

Страница 24: ...byshire DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufa...

Отзывы: