Type
VUW
VUW
242/1 E B
282/1 E B
Countries of
GB, IE
GB, IE
Destination
Main burner jet size
16 x 7/075
18 x 7/075
number x mark.
Burner setting pressure
25.1 (9.9) Propane
26.6 (10.5) Propane
mbar (in W.G.)
19.3 (7.6) Butane
20.6 (8.1) Butane
mbar (in W.G.)
Restrictor
2 * 350
2 * 375
marking
Delivered gas
Propane
G 31 96.65
MJ/m
3
Gross C.V. (s.t.)
G 30 125.81
MJ/m
3
Gas consumption (s.t.)
1.09 (Propane)
1.27 (Propane)
m
3
/h
0.84 (Butane)
0.98 (Butane)
m
3
/h
59
Technical Data
L.P.G. Appliances:
VUW 242/1 EB
VUW 282/1 EB
The appliance delivered is designed
for use with LPG.
Please read the instructions for
installation therefore as follows:
Related documents to be
supplemented by:
BS 5482:
CP for domestic butane
and propane gas
burning installations
Part 1:
Installations in
permanent dwellings
Inlet pressure: Propane
37 mbar (14.6 in W.G.)
Butane
28-30 mbar
(11.0-11.8 in W.G.)
11. Supplementary
information for
TURBOmax