![Vaillant sensoCOMFORT VRC 720 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/vaillant/sensocomfort-vrc-720/sensocomfort-vrc-720_operating-and-installation-instructions_848828039.webp)
-- Using the functional modules, basic system diagram, start-up 4
0020287900_00
sensoCOMFORT
Operating and installation instructions
37
4.9.5
Basic system diagram 0020280010
4.9.5.1 Special features of the system
5: The cylinder temperature cut-out must be installed in a suitable location in order to avoid cylinder temperatures
above 100 °C.
4.9.5.2 Settings on the system control
Basic system diagram code:
1
FM5 configuration:
2
FM5 MO: Anti-legio. pump
Circuit 1
/
Circuit type: Heating
Circuit 1
/
Room temp. mod.: Active
or
Expanded
Circuit 2
/
Circuit type: Heating
Circuit 2
/
Room temp. mod.: Active
or
Expanded
Circuit 3
/
Circuit type: Heating
Circuit 3
/
Room temp. mod.: Active
or
Expanded
Zone
1/
Zone activated: Yes
Zone
1 /
Zone assignment: Rem. contr. 1
Zone
2/
Zone activated: Yes
Zone
2 /
Zone assignment: Rem. contr. 2
Zone
3/
Zone activated: Yes
Zone
3 /
Zone assignment: Control
4.9.5.3 Settings at the remote control
Remote control address:
(1): 1
Remote control address:
(2): 2