32
Operating and installation instructions 0020334316_02
4.7.4
Heat pump as a single unit (hybrid)
With external back-up boiler
A back-up boiler (with eBUS) is connected via the
VR 32
(address 2).
A back-up boiler (without eBUS) is connected to the output for the heat pump or the heat pump control module for the ex-
ternal back-up boiler.
System property
Basic system diagram
code:
Without
heat ex-
changer
1)
With heat
exchanger
1)
Domestic hot water generation only provided by the back-up boiler without the functional module
–
Connecting the domestic hot water cylinder temperature sensor to a back-up boiler (separate charge
control)
8
10
Domestic hot water generation only provided by the back-up boiler with the functional module
–
Connecting the domestic hot water cylinder temperature sensor to a back-up boiler (separate charge
control)
9
10
Domestic hot water generation through the heat pump and back-up boiler
–
Connecting the domestic hot water cylinder temperature sensor to the FM5 functional module
–
Without the FM5 functional module, connecting the domestic hot water cylinder temperature sensor
to the heat pump control module and/or heat pump
16
16
Domestic hot water generation provided by the heat pump and back-up boiler with a bivalent domestic
hot water cylinder
–
Connecting the upper domestic hot water cylinder temperature sensor to a back-up boiler (separate
charge control)
–
Connecting the lower domestic hot water cylinder temperature sensor to the heat pump control
module and/or heat pump
12
13
1) E.g.
VWZ MWT
4.7.5
Cascade with heat pumps
Maximum seven heat pumps possible
With external back-up boiler
As of the second heat pump, the heat pumps and, if required, the heat pump control modules, are connected via the
VR 32
(B)
(address 2 to 7).
A back-up boiler (with eBUS) is connected via the
VR 32
(next free address).
A back-up boiler (without eBUS) is connected to the output for the first heat pump or the heat pump control module for the
external back-up boiler.
System property
Basic system diagram
code:
Without
heat ex-
changer
1)
With heat
exchanger
1)
Domestic hot water generation provided by the back-up boiler only
–
Connecting the domestic hot water cylinder temperature sensor to a back-up boiler (separate charge
control)
9
–
Domestic hot water generation through the heat pump and back-up boiler
–
Connecting the domestic hot water cylinder temperature sensor to the FM5 functional module
16
16
1) E.g.
VWZ MWT
Содержание sensoCOMFORT VRC 720/3
Страница 2: ...2 en Operating and installation instructions 3 en Country specifics 59...
Страница 37: ...0020334316_02 Operating and installation instructions 37 4 9 2 2 Basic system diagram 0020184677...
Страница 38: ...38 Operating and installation instructions 0020334316_02 4 9 2 3 Wiring diagram 0020184677...
Страница 43: ...0020334316_02 Operating and installation instructions 43 4 9 4 4 Basic system diagram 0020177912...
Страница 44: ...44 Operating and installation instructions 0020334316_02 4 9 4 5 Wiring diagram 0020177912...
Страница 46: ...46 Operating and installation instructions 0020334316_02 4 9 5 4 Basic system diagram 0020280010...
Страница 47: ...0020334316_02 Operating and installation instructions 47 4 9 5 5 Wiring diagram 0020280010...
Страница 49: ...0020334316_02 Operating and installation instructions 49 4 9 6 4 Basic system diagram 0020260774...
Страница 50: ...50 Operating and installation instructions 0020334316_02 4 9 6 5 Wiring diagram 0020260774...
Страница 60: ...60 Country specifics 0020334316_02 Vaillant 4 6 5 Vaillant 6 Vaillant 7 8 10 9 7 8 3 9 0800 501 805...
Страница 61: ......
Страница 62: ......
Страница 63: ......