1. Press to select other mode during standby
status ; or
2. Remote control get the priority (if applicable)
5 Detecting and rectifying faults
8
Operating instructions turboMAG pro 0020208984_00
4.7
Stopping ECO mode
m
4.8
Setting the bath-filling mode
1.
To switch from normal operating mode to bath-filling
mode while in standby, press
m
m
twice.
The water volume display flashes. (Factory setting:
160 L)
2.
Press
or
to set the water volume. Then wait 3
seconds.
3.
Press
or
to set the water temperature.
Default setting: 42 °C
4.
Open the water tap.
The display shows the current water temperature.
Note
An audible signal sounds 10 L before the set
water volume is reached and when thevolume
is reached.
The product does not end bath-filling mode
automatically.
4.9
Exiting bath-filling mode
1. Close the water tap for 10 minutes
; or
2. Press to select other mode during standby status
; or
3. Press (on/off button)
; or
4. When the water volume is 10 L below the set water , close
the water tap
; or
5. Switch off the external on/off switch
; or
6. Remote control get the priority ( if applicable )
4.10
Setting the priority for the remote controls
1.
Close all of the hot water valves.
2.
On the product, press and hold the
m
button to prior-
itise the control elements on the product. Alternatively,
on a remote control, briefly press the
button to prior-
itise the remote control.
–
The symbol displaying the prioritisation lights up on
the display.
Displayed symbols (
→
Page 6 )
5
Detecting and rectifying faults
Fault messages have priority over all other displays.
If faults occur or fault messages are displayed , proceed
as set out in the table in the appendix.
Detecting and rectifying faults (
→
Page 10 )
If the product still does not function without problems
after the checks have been carried out using the table ,
contact a competent person to rectify the problem.
6
Care and maintenance
6.1
Maintenance
An annual inspection and maintenance of the product every
18 months carried out by a competent person is
a prerequisite for ensuring that the product is permanently
ready and safe for operation, reliable, and has a long work-
ing life.
6.2
Caring for the product
Caution.
Risk of material damage caused by un-
suitable cleaning agents.
Do not use sprays , scouring agents , de-
tergents, solvents or cleaning agents that
contain chlorine.
Clean the casing with a damp cloth and a little solvent-
free soap.
7
Decommissioning
7.1
Temporarily decommissioning the product
Close the cold water stop valve.
Open the water tap to allow the rest of the water to flow
out of the line.
Close the water tap.
Close the hot water stop valve.
Close the gas isolator cock.
Disconnect the product from the power mains.
Содержание MAG HK 13-2/0-3 H
Страница 11: ......