background image

1.       Press        to select  other mode during standby 

           status ; or

2.       Remote control get the priority (if applicable)

5 Detecting and rectifying faults

8

Operating instructions turboMAG pro 0020208984_00

4.7

Stopping ECO mode

m

4.8

Setting the bath-filling mode

1.

To switch from normal operating mode to bath-filling

mode while in standby, press

m

m

twice.

The water volume display flashes. (Factory setting:

160 L)

2.

Press

or

to set the water volume. Then wait 3

seconds.

3.

Press

or

to set the water temperature.

Default setting: 42 °C

4.

Open the water tap.

The display shows the current water temperature.

Note

An audible signal sounds 10 L before the set

water volume is reached and when thevolume
is reached.
The product does not end bath-filling mode

automatically.

4.9

Exiting bath-filling mode

1.    Close the water tap for 10 minutes

; or

2.    Press           to select other mode during standby status

; or

3.    Press           (on/off button)

; or

4.    When the water volume is 10 L below the set water , close 
       the water tap

; or

5.    Switch off the external on/off switch

; or

6.    Remote control get the priority ( if applicable )

4.10

Setting the priority for the remote controls

1.

Close all of the hot water valves.

2.

On the product, press and hold the

m

button to prior-

itise the control elements on the product. Alternatively,

on a remote control, briefly press the

button to prior-

itise the remote control.

The symbol displaying the prioritisation lights up on

the display.

Displayed symbols (

Page 6 )

5

Detecting and rectifying faults

Fault messages have priority over all other displays.

If faults occur or fault messages are displayed , proceed

as set out in the table in the appendix.
Detecting and rectifying faults (

Page 10 )

If the product still does not function without problems

after the checks have been carried out using the table ,

contact a competent person to rectify the problem.

6

Care and maintenance

6.1

Maintenance

An annual inspection and maintenance of the product every

18 months carried out by a competent person is

a prerequisite for ensuring that the product is permanently

ready and safe for operation, reliable, and has a long work-

ing life.

6.2

Caring for the product

Caution.
Risk of material damage caused by un-

suitable cleaning agents.

Do not use sprays , scouring agents , de-

tergents, solvents or cleaning agents that

contain chlorine.

Clean the casing with a damp cloth and a little solvent-

free soap.

7

Decommissioning

7.1

Temporarily decommissioning the product

Close the cold water stop valve.
Open the water tap to allow the rest of the water to flow

out of the line.
Close the water tap.
Close the hot water stop valve.
Close the gas isolator cock.
Disconnect the product from the power mains.

Содержание MAG HK 13-2/0-3 H

Страница 1: ...erghauser Str 40 D 42859 Remscheid Telefon 02191 18 0 Telefax 021 91 18 28 10 info vaillant de www vaillant de Operating instructions MAG HK 13 2 0 3 H back flue MAG HK 13 2 0 3 B back flue MAG HK 17...

Страница 2: ...6 Recommended hot water temperature settings 6 4 Operation 7 4 1 Preparing for start up 7 4 2 Starting up the product 7 4 3 Switching on the product 7 4 4 Selecting operating modes 7 4 5 Setting the...

Страница 3: ...e carried out by children unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct...

Страница 4: ...gas installation to the expansion relief valve to the drain lines to constructional conditions that may affect the operational reliability of the product 1 3 9 Risk of injury and material damage due...

Страница 5: ...solutely sure that the product is compat ible with the gas group at the installation site 3 2 Output ranges Type designation Power Water flow rate T 25 K MAG HK 13 2 0 3 H back flue MAG HK 13 2 0 3 H...

Страница 6: ...water temperature settings 38 39 40 41 42 43 44 45 46 47 48 49 70 1 2 3 1 Washing dishes showering 2 Showering hot water 3 High temperature The hot water temperature can be set from 38 C to 70 C defau...

Страница 7: ...witch on the power supply to the product 6 Open the gas isolator cock 2 4 2 Starting up the product Only start up the product once the casing has been com pletely closed 4 3 Switching on the product 1...

Страница 8: ...elements on the product Alternatively on a remote control briefly press the button to prior itise the remote control The symbol displaying the prioritisation lights up on the display Displayed symbols...

Страница 9: ...is sion the product 8 Guarantee and customer service 8 1 Guarantee For information on the manufacturer s guarantee you can write to the contact address that is provided on the back page 8 2 Customer s...

Страница 10: ...ischarge the cold water Vapour at the flue gas open ing The water in the flue gas condenses in the cold air Hot water is white Air that is dissolved in the cold water escapes After closing the hot wat...

Страница 11: ......

Страница 12: ...0020208984_00 21 04 2015 These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent...

Отзывы: