Appendix
0020250180_00 geoTHERM Installation and maintenance instructions
33
Setting level
Values
Unit
Increment, select
Default setting
Setting
Min.
Max.
T.147 DCF status
No DCF signal
Validate DCF signal
Valid DCF signal
Installer level
→
Configuration
→
Language
Current language
01 Deutsch
02 English
03 Français
06 Nederlands
16 Norsk
18 Čeština
20 Slovenščina
27 Suomi
02 English
Contact data
Phone number
0 - 9
Compressor starts at
−
999
0
°min
1
−
60
Comp. hysteresis
3
15
K
1
7
Max. rem. feed head
200
700
mbar
1
700
Conf. heat. build. pump
1
100
%
1, auto
Auto
Conf. cool. build. pump
1
100
%
1, auto
Auto
Conf. DHW build. pump
1
100
%
1, auto
Auto
Reset anti-cycl. time
0
120
min
1
0
Boiler supp. set p.
1)
300
1300
l/h
20
1000
Enviro. pump set p.
29
100
%
1
75
Freeze protection
−
14
5
℃
1
−
7
Enable emergency mode
On, Off
Off
Software version
Current value for the
main PCB (HMU xxxx)
and the display (AI
xxxx)
Installer level
→
Resets
→
Switch-on delay
Yes, No
No
Statistics
Yes, No
No
Factory settings
Yes, No
No
Installer level
→
Start inst. assistant
→
Language
01 Deutsch
02 English
03 Français
06 Nederlands
16 Norsk
18 Čeština
20 Slovenščina
27 Suomi
02 English
Freeze protection
−
13
4
℃
1
−
7
Check programme
P.05 Purge building
circuit
P.06 Purge environment
circuit
P.07 Purge environment
and building circuit
Contact data
Phone number
0 - 9
1)
Can only work in conjunction with the VWZ ZK accessory.
2)
Fault lists (section 9.1) are only available, and can only be deleted, if faults have occurred.