0020197272_02 Installation instructions
7
Danger!
Risk of damage caused by incorrect in-
stallation.
Connecting wires that have been stripped
too far may cause short circuits and damage
the electronics if a strand accidentally comes
loose.
▶
Only strip the outer sheathing of flexible
ducts to a maximum of 2.5 cm to prevent
short circuits.
▶
Lay the lines correctly.
▶
Use the strain relief.
4.
Strip the outer sheathing of the line, without damaging
the sheathing on the connecting wires.
Connecting the line to the upper terminal block
C
B
D
≤25 mm
A
5.
Push the line that is to be connected between the wall
and wall base to the upper terminal block.
6.
Connect the required inputs and outputs in accordance
with the illustration.
7.
Connect the eBUS line to the terminal block on the
PCB. In doing so, ensure that you comply with the po-
larity in the system.
Connecting the line to the lower terminal block
B
E
D
C
≤25 mm
A
8.
Connect all of the required lines in accordance with the
illustration.
9.
Install the front casing. (
6
Decommissioning
6.1
Decommissioning the heating installation
▶
Decommission all system components of the heating
installation, as described in the installation instructions
for the individual system components.
6.1.1
Removing the product from the wall
1.
Remove the front casing. (
2.
Disconnect the lines from the product's terminal block.
3.
Unscrew the wall base from the wall.
7
Recycling and disposal
This product is an electrical or electronic unit within the con-
text of EU Directive 2012/19/EU. The unit was developed
and manufactured using high-quality materials and compon-
ents. These can be recycled and reused.
Find out about the regulations that apply in your country re-
garding the separate collection of waste electrical or elec-
tronic equipment. Correctly disposing of old units protects
the environment and people against potential negative ef-
fects.
▶
Dispose of the packaging correctly.
▶
Observe all relevant regulations.