Safety 1
0020213395_00 flexoTHERM exclusive Installation and maintenance instructions
5
1.3.4 Risk of material damage caused by
frost
▶
Do not install the product in rooms prone
to frost.
1.3.5 Risk of death from electric shock
There is a risk of death from electric shock if
you touch live components.
Before commencing work on the product:
▶
Disconnect the product from the power
supply by switching off all power supplies
(electrical partition with a contact opening
of at least 3 mm, e.g. fuse or line protec-
tion switch).
▶
Secure against being switched back on
again.
▶
Wait for at least 3 minutes until the capa-
citors have discharged.
▶
Check that there is no voltage.
1.3.6 Risk of injury due to chemical burns
caused by brine fluid
The brine fluid ethylene glycol is harmful to
health.
▶
Avoid contact with the skin and eyes.
▶
Always wear gloves and protective
goggles.
▶
Do not inhale or swallow.
▶
Observe the safety data sheet that accom-
panies the brine fluid.
1.3.7 Risk of burns due to hot and cold
components
There is a risk of burns from any uninsulated
pipelines and from the auxiliary electric heat-
ing.
▶
Only carry out work on the components
once they have reached ambient temperat-
ure.
1.3.8 Material damage due to unsuitable
installation surface
The installation surface must be even and
have sufficient load-bearing capacity to sup-
port the operating weight of the product. An
uneven installation surface may cause leaks
in the product.
If the installation surface does not have suffi-
cient load-bearing capacity, the product may
topple.
There is a risk of death if the connections are
subject to leaks.
▶
Make sure that the product is positioned
flush against the installation surface.
▶
Ensure that the installation surface has
sufficient load-bearing capacity to bear the
operating weight of the product.
1.3.9 Danger due to malfunctions
Ensure that the heating installation is in a
technically perfect condition.
▶
Ensure that no safety or monitoring
devices have been removed, bridged or
disabled.
▶
Immediately rectify any faults and damage
that may affect safety.
▶
Install the controller in a location where it is
not covered by furniture, curtains, or other
objects.
▶
If thermostatic control is activated, ad-
vise the operator that, in the room where
the controller is mounted, all the radiator
valves must be fully open.
▶
Do not use the units' free terminals as sup-
porting terminals for other wiring.
▶
At lengths of over 10 m, 230 V supply lines
must be laid separately from sensor or bus
lines.
1.3.10 Preventing the risk of injury from
freezing as a result of touching
coolant
The product is supplied with an operational
filling of R 410 A refrigerant. Escaping
coolant may cause freezing if the exit point is
touched.
▶
If coolant escapes, do not touch any com-
ponents of the product.
▶
Do not inhale any vapours or gases that
escape from the refrigerant circuit as a
result of leaks.
▶
Avoid skin or eye contact with the coolant.
▶
In the event of skin or eye contact with the
coolant, seek medical advice.