Instructions for installation and servicing ecoTEC 839592_12
Display Meaning
Display value/adjustable value
d.36
Hot water flow sensor
in l/min
d.40
Flow temperature
Actual value in °C
d.41
Return temperature
Actual value in °C
d.44
Digitised ionisation potential
Display range of 0 to 102, > 80 no flame, < 40 even flame
d.47
Outside temperature
(with weather compensating Vaillant controller only)
Actual value in °C
d.67
Remaining burner anti cycling time
in min
d.76
Appliance variant (device specific number)
00 to 99
d.90
Digital regulator status
1 = identified, 0 = unidentified (eBUS Address <=10)
d.91
DCF status with connected external probe with DCF77
receiver
0 = no reception, 1 = reception, 2 = synchronised, 3 = valid
d.97
Activation of the second diagnostic level
Password: 17
Table 8.2 Diagnostic codes of the first diagnostic level
(continued)
Second diagnostic level
• As described above in the first diagnostic level, scroll
through the diagnostic number
d.97
.
• Change the displayed value to
17
(password) and
press the “
i
” button.
You are now in the second diagnostic level where all
information from the first diagnostic level (see Table
8.2) and the second diagnostic level (see Table 8.3) is
displayed.
Display Meaning
Display value/adjustable value
d.17
Heating flow/return regulation changeover
0 = flow, 1 = return (factory setting: 0)
d.18
Pump mode (return)
0 = return, 1 = nonstop, 2 = winter (factory setting: 0)
d.19
Only in ecoTEC plus:
Operating modes of the two-speed heating pump
0 = pre ignition speed 1, hot water or heating speed 2, overrun speed
1
1 = pre ignition speed 1, hot water speed 2, heating speed 1, overrun
speed 1
2 = like 1, but speed in heating mode dependent on heating part
load d. 0 (if d.0 is below 60% of full load, then pump speed 1,
otherwise speed 2)
3 = always speed 2
(factory setting: 2)
d.20
Maximum set value for target cylinder temperature
(system boilers only)
Setting range: 50 to 70 °C (factory setting: 65 °C)
d.27
Switching accessory relay 1 in the accessory module
1 = Circulation pump (default)
2 = Ext. pump
3 = Storage charging pump
4 = Flue gas flap/extractor hood
5 = External gas valve
6 = External error message
d.28
Switching accessory relay 2 in the accessory module
1 = Circulation pump
2 = Ext. pump (default)
3 = Storage charging pump
4 = Flue gas flap/extractor hood
5 = External gas valve
6 = External error message
Table 8.3 Diagnostics codes of the second diagnostic level
Scrolling and changing values and exiting the diagnostic
mode is done as described in the first diagnostic level.
Note
After exiting the second diagnostic level, if you
press “i” and “+” within 4 minutes, you will
directly reach the second diagnostic level
without having to enter the password again.
Troubleshooting 8
Содержание ecoTEC SERIES
Страница 59: ...Appendix EG declaration of conformity Appendix...
Страница 60: ...Installation Commissioning and Service Record Installation Commissioning and Service Record...
Страница 61: ...Please affix the label from the rear cover of the control box over this area...
Страница 63: ......
Страница 64: ...839592_12 GBIE 062010 Subject to alterations...