Live monitor (current status of the boiler)
22
Operating instructions ecoTEC pro 0020129673_00
8
8
Live monitor (current status of the
boiler)
This function allows you to read the current status of your
boiler.
S.04
8.1 Current status of the boiler; example)
>
Press both selection buttons at the same time
+
.
The display is automatically updated if the boiler status
changes.
Status code Meaning
Displays in heating mode
S.00
Heating no heat requirement
S.02
Heating mode Pump flow
S.03
Heating mode Ignition
S.04
Heating mode Burner on
S.06
Heating mode fan slow down
S.07
Heating mode Pump wake
S.08
Heating, remaining cut-off time xx min
Displays during DHW mode
S.10
Hot water demand via fan sensor
S.14
DHW mode Burner on
Displays in cylinder charging mode
S.20
DHW demand
S.22
DHW mode Pump running
Special cases
S.31
No heat requirement Summer operation
S.34
Heating mode, frost protection
8.1 Possible appliance statuses (selection)