32
Installation and maintenance instructions 0020308121_04
8
Operation
8.1
Operating concept
The operating concept, the operation of the product and the
read-out and setting options in the end user level are de-
scribed in the operating instructions.
An overview of the read-out and setting options for the in-
staller level is included in the "Installer level" table in the ap-
pendix.
8.2
Calling up the installer level
1.
Navigate to
MENU
→
SETTINGS
→
Installer level
and
confirm by pressing
.
2.
Set the code for the installer level and confirm by
pressing
.
–
Code for Installer level: 17
8.2.1
Exiting the installer level
▶
Press
.
◁
The basic display is shown.
8.3
Calling up/setting diagnostics codes
1.
Call up the installer level. (
2.
Navigate to the
Diagnostics codes
menu item.
3.
Use the scrollbar to select the required diagnostics
code.
4.
Confirm by pressing
.
5.
Use the scrollbar to select the required value for the
diagnostics code.
Diagnostics codes (
6.
Confirm by pressing
.
7.
If required, repeat work steps 2 to 6 to set additional
diagnostics codes.
8.3.1
Exiting the diagnostics codes
▶
Press
.
◁
The basic display is shown.
8.4
Running a check programme
1.
Call up the installer level. (
2.
Navigate to the
Test modes
→
Check programmes
menu item.
3.
Use the scrollbar to select the required check pro-
gramme.
Check programmes (
4.
Confirm by pressing
.
◁
The check programme starts and runs through
checks.
◁
If you have selected check programme
P.001
, set
the desired load and then confirm by pressing
.
5.
While the check programme is running, press
, if
required, to display the
Data overview
.
6.
If required, select another check programme.
8.4.1
Exiting a check programme
▶
Press
.
◁
The basic display is shown.
8.5
Carrying out the actuator test
1.
Call up the installer level. (
2.
Navigate to the
Test modes
→
Actuator test
menu
item.
3.
Use the scrollbar to select the required actuator test.
Actuator test (
4.
Confirm by pressing
.
◁
The actuator test starts and runs through.
5.
While the actuator test is running, press
, if
required, to display the following:
Data overview
.
6.
If required, select another actuator test.
8.5.1
Exiting the actuator test
▶
Press
.
◁
The basic display is shown.
8.6
Calling up the data overview
1.
Call up the installer level. (
2.
Navigate to the
Data overview
menu item.
◁
The current operating mode is shown in the display.
8.7
Calling up status codes
▶
Navigate to
MENU
→
INFORMATION
→
Status code
.
Status codes (
◁
The current operating mode (status code) is shown
on the display.
8.7.1
Exiting the status codes
▶
Press
.
◁
The basic display is shown.
8.8
Exiting the menu level
▶
Press
.
◁
The basic display is shown.
8.9
Running the chimney sweep mode
(combustion analysis)
1.
Press
.
2.
Press
or navigate to
MENU
→
SETTINGS
→
Chim-
ney sweep mode
.
3.
To carry out the combustion analysis, select one of the
following heat loads:
–
Adjustable heat load
–
Max. DHW heat input
–
Min. heat input
4.
Confirm by pressing
.
◁
If you have selected
Adjustable heat load
, set the
desired heat load and confirm by pressing
.
◁
If status code
S.093
is displayed, calibration is be-
ing carried out.