14
Installation and maintenance instructions 0020244997_07
Technical data
–
Electrics
VU 126/5-
5 (H-GB)
ecoTEC plus
612
VU 156/5-
5 (H-GB)
ecoTEC plus
615
VU 186/5-
5 (H-GB)
ecoTEC plus
618
VU 186/5-
5 (P-GB)
ecoTEC plus
618
VU 246/5-
5 (H-GB)
ecoTEC plus
624
VU 306/5-
5 (H-GB)
ecoTEC plus
630
Electric connection
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
Permissible connected
voltage
190 to 253 V
190 to 253 V
190 to 253 V
190 to 253 V
190 to 253 V
190 to 253 V
Built-in fuse (slow-blow)
2 A
2 A
2 A
2 A
2 A
2 A
Min. electrical power con-
sumption
35 W
35 W
35 W
35 W
35 W
45 W
Max. electrical power
consumption
55 W
60 W
65 W
65 W
70 W
90 W
Electrical power con-
sumption, standby
< 2 W
< 2 W
< 2 W
< 2 W
< 2 W
< 2 W
Level of protection
IP X4 D
IP X4 D
IP X4 D
IP X4 D
IP X4 D
IP X4 D
VU 306/5-
5 (P-GB)
ecoTEC plus
630
VU 386/5-
5 (H-GB)
ecoTEC plus
637
VUW 196/5-
5 (H-GB)
ecoTEC plus
825
VUW 246/5-
5 (H-GB)
ecoTEC plus
832
VUW 246/5-
5 (P-GB)
ecoTEC plus
832
VUW 306/5-
5 (H-GB)
ecoTEC plus
835
Electric connection
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
230 V/50 Hz
Permissible connected
voltage
190 to 253 V
190 to 253 V
190 to 253 V
190 to 253 V
190 to 253 V
190 to 253 V
Built-in fuse (slow-blow)
2 A
2 A
2 A
2 A
2 A
2 A
Min. electrical power con-
sumption
45 W
55 W
35 W
35 W
35 W
45 W
Max. electrical power
consumption
80 W
95 W
80 W
85 W
85 W
90 W
Electrical power con-
sumption, standby
< 2 W
< 3 W
< 2 W
< 2 W
< 2 W
< 2 W
Level of protection
IP X4 D
IP X4 D
IP X4 D
IP X4 D
IP X4 D
IP X4 D
VUW 286/5-
5 (H-GB)
ecoTEC plus
838
Electric connection
230 V/50 Hz
Permissible connected
voltage
190 to 253 V
Built-in fuse (slow-blow)
2 A
Min. electrical power con-
sumption
55 W
Max. electrical power
consumption
120 W
Electrical power con-
sumption, standby
< 3 W
Level of protection
IP X4 D