5 Installation
12
Installation and maintenance instructions ecoTEC exclusive 0020189875_01
1
2.
Install the discharge pipe as shown (do not shorten).
3.
Make sure that the end of the pipe is visible.
4.
Ensure that discharged water or steam cannot cause
injury to persons or damage to electronic components.
5.8
Flue installation
5.8.1
Installing and connecting the flue pipe
1.
You can find out which flue pipes may be used by con-
sulting the enclosed flue pipe installation manual.
Conditions
: Installation in damp rooms
▶
You must connect the product to a room-sealed air/flue
gas installation. The combustion air must not be taken
from the installation room.
Caution.
Risk of poisoning due to escaping flue
gas.
Mineral-oil-based greases can damage the
seals.
▶
Instead of grease, use only water or com-
mercially available soft soap to aid install-
ation.
2.
Install the flue pipe using the installation manual.
5.8.2
Replacing the connection piece for the
air/flue pipe as required
1.
Replace the connection piece for the air/flue pipe as
required. The product-specific standard equipment is
listed under Technical Data in the appendix.
2.
Remove the connection piece for the air/flue pipe.
(
→
Page 12)
3.
Alternatives
▶
If required, install the connection piece for the
separate air/flue gas ducting, 80/80 mm diameter.
(
→
Page 12)
5.8.2.1 Removing the connection piece for the
air/flue pipe
A
B
C
1.
Insert a screwdriver into the slot between the measuring
stub pipes.
2.
Press the screwdriver carefully down.
3.
Turn the connection piece anticlockwise as far as it will
go and then remove it by pulling it upwards.
5.8.2.2 Installing the connection piece for the
separate air/flue gas ducting, 80/80 mm
diameter
1.
Remove the connection piece for the air/flue pipe.
(
→
Page 12)
120 mm
120 mm
2.
Insert the alternative connection piece. The connection
for the air supply can point to the left- or the right-hand
side. In doing so, pay attention to the latching lugs.
3.
Turn the connection piece clockwise until it clicks into
position.
5.9
Electrical installation
Only qualified electricians may carry out the electrical install-
ation.
Danger!
Risk of death from electric shock!
Mains connection terminals L and N remain
live even if the on/off switch is turned off.
▶
Switch off the power supply.
▶
Secure the power supply against being
switched on again.