4 Operation

Instructions for use ecoMAX

6

Fig. B.3.1 Opening the service valves (646)

Fig. B.3.2 Opening the service valves (665)

• Ensure that the service valves in the heating flow and

return (4 and 3) and the gas service valve (1) are open.

The flow, return and gas service valves are open when
the line marking has the same direction as the pipe.

Attention!

The pressure relief valve is provided for safety
reasons and must not be interfered with.

4.2.2 Checking the water contents

Fig. B.4 Checking the water contents

Check the water contents of the system on the pressure
gauge (1). 
The needle on the pressure gauge should be within the
green band (between 1 and 1.5 bar). If the needle dis-
plays a value below 0.8 bar when the appliance is cold,
follow the instructions left by your installer to refill the
system. 
Alternatively, your installer should be called to refill the
system.

4.3 Domestic hot water operation 

(ecoMAX 646 and 665 only)

Fig. Domestic hot water operation

ecoMAX 646 and 665 provides central heating and
domestic hot water where a separate indirect hot water
cylinder is also incorporated to the system.

Attention!

The boiler should only be used when the heating
system contains water. Use of the boiler without

water may cause damage to the boiler or its
components.

• Turn the main switch (2) to the “l” position.
• Set the maximum hot water temperature control to the

desired setting using the control knob (3). It means
- all the way to the very left = frost protection 15 °C
- all the way to the very right = max.70 °C

When the domestic hot water temperature is adjusted,
the boiler display will  show the corresponding water
temperature. This information appears on the display for
about 5 seconds and then the display returns to its nor-
mal state (current heating flow temperature e.g. 45 °C).

Note!

Domestic hot water operation with ecoMAX 635:
When the installation is equipped  with an exter-
nal hot water cylinder, your installer should have
instructed you how to set the temperature and
how to switch ON and OFF.

3

2

bar

2

1

3

0

bar

2

1

3

0

1

3

4

1

3

1

4

0020014608_00GB_032006  08.03.2006 17:15 Uhr  Seite 6

Содержание ecoMAX E SERIES

Страница 1: ...For the user GB Instructions for use ecoMAX Wall hung room sealed fan assisted condensing boilers...

Страница 2: ...display 5 4 2 Initial checks before turning ON 5 4 2 1 Opening the service valves 5 4 2 2 Checking the water contents 6 4 3 Domestic hot water operation ecoMAX 646 and 665 only 6 4 3 1 Obtaining hot...

Страница 3: ...ing from failure to observe these instructions 1 4 Specified use Vaillant ecoMAX appliances are made to fulfil the latest technical specifications and official safety regulations These appliances are...

Страница 4: ...ce agreement with your service agent or Vaillant Ltd Attention The device may only be used for initial operation for testing for continuous operation with the chamber cover closed and with the flue sy...

Страница 5: ...2 shows during nor mal operation current information on the heating system flow temperature Fig B 2 example gives flow temperature of 45 C In the event of a malfunction this temperature display is re...

Страница 6: ...665 only Fig Domestic hot water operation ecoMAX 646 and 665 provides central heating and domestic hot water where a separate indirect hot water cylinder is also incorporated to the system Attention T...

Страница 7: ...e is adjusted the boiler display will show the corresponding water temperature This infor mation appears on the display for about 5 seconds and then the display returns to its normal state current hea...

Страница 8: ...ttempts then the boiler does not go into ope ration and switches to Lock out This is indicated by a fault code F 28 or F 29 on the display A new attempt to ignite the flame can then only be per formed...

Страница 9: ...t illuminated see page 8 Attention If your boiler still does not operate then please consult your installer or Vaillant Service Solutions 0870 6060 777 4 9 Care and maintenance Clean the outer casing...

Страница 10: ......

Страница 11: ......

Страница 12: ...0020014608_00GB 03 2006 Subject to alteration...

Отзывы: