Fig. 11

EC_Regler_(24h_7d)_012/0

Release time clock blanking plate (1,
fig. 11) from the control box by 
pushing the retaining clips (2, fig. 11)
down. The time clock blanking plate
can now be pivoted forwards on 
locating lugs (3, fig. 11) and removed.

Using a sharp knife, carefully cut a slit
in the sealing grommet at the rear of
the time clock housing. Pass the
connecting lead through the grommet.

Insert time clock locating lugs (3, fig.
11) into control box and pivot upwards
to locate onto retaining clips.

(Note: The ribbon cable is supplied with
two plug in connectors. Always utilise 
the connector nearest to the timer.
The plug at the end of the cable is 
required when the timer is used as a 
spare part replacement for earlier 
TURBOmax/ECOmax boilers).

Содержание ECOmax 824 E

Страница 1: ...W 282 1 E ECOmax VUW 236 E VUW 286 E ECOmax 824 E 828 E 24 hour time clock Art No 300 880 7 day time clock Art No 300 881 NOTE This time clock must only be installed by a competent person All above li...

Страница 2: ...1a and pull lower door panel forward and down to release it from the top hinge pin 2 fig 1a Slide the top panel up to release the retaining clips 1 fig 1b Undo screw 1 fig 1c and lower front control p...

Страница 3: ...3 and removed Fit the time clock by first passing the connecting lead through the hole left by the time clock blanking plate Insert locating lugs 3 fig 3 into control box and pivot upwards to locate o...

Страница 4: ...d as shown in fig 13 Unless already carried out complete the electrical installation by connecting a 230 V 50 Hz electrical supply fused at 3A to the boiler as detailed in the boiler installation inst...

Страница 5: ...necting the plug at the socket outlet if there is an isolating switch only remove the fuse from the switch Remove bottom hinge screw 1 fig 1a and pull lower door panel forward and down to release it f...

Страница 6: ...me clock by first passing the connecting lead through the hole left by the time clock blanking plate Insert time clock locating lugs 3 fig 7 into control box and pivot upwards to locate onto retaining...

Страница 7: ...wire should be removed and the room thermostat connected as shown in fig 13 Unless already carried out complete the electrical installation by connecting a 230 V 50 Hz electrical supply fused at 3A t...

Страница 8: ...the mains electricity supply by disconnecting the plug at the socket outlet if there is an isolating switch only remove the fuse from the switch Lower control panel cover Remove screw 1 fig 9a Releas...

Страница 9: ...1 fig 10a and lower control box Disconnect HT lead from rear of control box 1 fig 10b Release mains electrical lead from securing clip on rear of control box 2 fig 10b Release control box rear cover r...

Страница 10: ...arefully cut a slit in the sealing grommet at the rear of the time clock housing Pass the connecting lead through the grommet Insert time clock locating lugs 3 fig 11 into control box and pivot upward...

Страница 11: ...ed and the room thermostat connected as shown in fig 13 Unless already carried out complete the electrical installation by connecting a 230 V 50 Hz electrical supply fused at 3A to the boiler as detai...

Страница 12: ...r_ 24h_7d _006 0 Boiler Terminal Strip Refer to boiler installation instructions for full wiring details 4 Connecting a room thermostat 5 Timer operation Note The timer switch contacts are Closed Duri...