4.8.5 Wiring diagram
Electronics box
Fan
230 V connection
Ignition electrode
Gas fitting
Water pressure switch
9
8
7
5
4
3
N
L
N
L
Pump 2. Pump
Contact-
T herm
L N
2 4V I
2 3 0V
R T 2 4V
2 3 0V
R T 2 3 0V
X 2/4 red
X 2/10 white
X 2/15 blue
X 2/8 black
X 2/20 black
X 4
X 10
X 7
X 8
X 6
X 2
X 2/9 red (22 VDC)
X 2/24 blue (earth)
X 2/12 blue (earth)
X 2/7 grey (PWM)
X 2/3 black (hall signal)
X 2/17 red (22 VDC)
X 2/23 black (earth)
X 2/6 brown (signal)
C1/C2 connector
(volt free switching cylinder thermostat)
Cylinder NTC connection
(Article number 306 257)
tank sensor
(plug colour: white)
Coding resistance
13
1
1 1 1
1
X 2/24 black (earth)
X 2/2 orange (signal)
Plug-in coupling
Water flow switch
Plug-in couplings
Integral pump
Flow NTC
Return NTC
Fig. 4.14 Wiring diagram ecoMAX 665