background image

V 7-025 NW
V 7-035 NW
V 7-050 M2N
V 7-060 M2N
V 7-075 M3N
V 7-085 M3N

climaVAIR

DE, EN, ES, HR, IT, NL

Содержание climaVAIR V 7-085 M3N

Страница 1: ...V 7 025 NW V 7 035 NW V 7 050 M2N V 7 060 M2N V 7 075 M3N V 7 085 M3N climaVAIR DE EN ES HR IT NL...

Страница 2: ...For the user User Manual Air Conditioner climaVAIR Split Type EN V 7 025 NW V 7 035 NW V 7 050 M2N V 7 060 M2N V 7 075 M3N V 7 085 M3N...

Страница 3: ...cal Airflow 14 7 6 2 Horizontal Airflow 15 7 7 Special Function Selection 15 7 7 1 Health Anion Operation HEALTH 15 7 7 2 Health Airflow Operation HEALTH FLOW 16 7 7 3 SLEEP Function 17 7 7 4 TIMER ON...

Страница 4: ...and in the user manual Vaillant does not accept any responsability for damages that may arise from non observation of the following instructions Note The Installation of the unit has to be done by qua...

Страница 5: ...h the standard in force with regard to obtaining the CE Marking 5 Description of the Unit This unit is comprised of the following elements Outdoor unit Indoor unit Remote controller and holder Connect...

Страница 6: ...ing strange odours and maintaining a fresh atmosphere This filter s exposure to sunlight regenerates its anti odour capacity Anti bacterial filter Filter with an anti allergic and anti bacterial effec...

Страница 7: ...here is anything still showing on display just press the reset button Remove the batteries in case the air conditioning is out of use for a long period If there is anything still showing on display ju...

Страница 8: ...face If the refrigerant spurts out and gets into your eyes it may result in serious eye injuries Do not interrupt the operation of the air conditioning unit by pulling the cord Danger of injury and ph...

Страница 9: ...N button AIRFLOW DIRECTION UP DOWN 15 SWING LEFT RIGHT button AIRFLOW DIRECTION LEFT RIGHT 16 FRESH button 17 SET button SETTING 18 POWER SOFT button 19 RESET button 7 2 2 Display Indicators Fig 7 2 O...

Страница 10: ...nection Disconnection of the Unit In order to connect the unit Press the ON button on the indoor unit or on the remote controller the unit will start to operate The liquid crystal display LCD will sho...

Страница 11: ...ress the TEMP buttons to select the temperature setting When pressing the TEMP buttons the temperature configuration will increase or decrease by 1 C When keeping the TEMP buttons pressed the temperat...

Страница 12: ...or decrease by 1 C When keeping the TEMP buttons pressed the temperature configuration will increase or decrease quickly Press the FAN button to select the fan speed Each time the FAN button is press...

Страница 13: ...on mode Legend 1 MODE button 2 FAN mode indicator 3 FAN button In order to activate the fan mode FAN With the unit connected see section 7 4 Press the MODE button The different operation modes are dis...

Страница 14: ...lect the heating operation mode HEAT Press the TEMP buttons to select the temperature setting When pressing the TEMP buttons the temperature configuration will increase or decrease by 1 C When keeping...

Страница 15: ...s recommendable to direct the grates vertically Note In cooling mode it is recommendable to direct the grates horizontally 7 6 1 Vertical Airflow Press the SWING UP DOWN button to direct the airflow u...

Страница 16: ...h Anion Operation HEALTH The anion generator of the air conditioning unit has the following functions To generate anions to neutralise the quantity of cations and anions in the air To kill bacteria To...

Страница 17: ...and the airflow will circulate horizontally from the top inlet and outlet grates Press the HEALTH FLOW button again to direct vertically The vertical flow indicator will appear on the display The unit...

Страница 18: ...T1 Configured temperature to Start of the SLEEP function In HEAT mode The ambient temperature decreases 2 C in relation to the configured one to ensure that the temperature does not rise excessively...

Страница 19: ...e desired time When pressing the HOUR buttons the time configuration will increase or decrease by 1 minute If the HOUR buttons are kept pressed the time will increase or decrease rapidly The time can...

Страница 20: ...tically in HI high for 15 minutes in order to put the configuration back to its original state To cancel the POWER function Press the POWER SOFT button twice The indicator will disappear To activate t...

Страница 21: ...operation operation test switch Legend 1 Emergency operation operation test switch Note When in emergency operation the dehumidifying mode is not available 7 8 2 Operation Test Only use this function...

Страница 22: ...m is heated In addition to the surfaces which delimit this area i e the walls doors windows ceiling and floor the adjacent rooms are also heated uncontrollably thermal energy is unintentionally lost I...

Страница 23: ...ure in cooling mode or excessively low in heating mode Set the temperature properly Obstacle in front of the air inlet or outlet Remove the obstacle to allow the air to circulate properly The ambient...

Страница 24: ...il it is released from the stopper and remove the filter downwards Clean the filter removing the dust or the dirt using a vacuum cleaner or cleaning them with cold water Ensure that the filters are dr...

Страница 25: ...ry precautions are taken In order to do so follow the steps described in the installation manual in reverse order and use the necessary tools and protection resources Ensure that the disassembly is ca...

Страница 26: ......

Отзывы: