4 On-roof fitting and installation
20
Installation manual auroTHERM exclusive 0020077994_02
4.1.8.1
n
Adjacent array configuration
A
C
D
B
B B
B
A
A
1.
Define the clearances of the roof brackets.
Quantity
A
B
C
D
VTK
570/2
VTK
1140/2
‑
1
1663 * /
1638 **
100 -
200
VTK
1140
997 -
1197
‑‑‑‑‑
VTK
570
507 -
607
1397
‑
2
2794
‑
3
4191
‑
4
5588
‑
5
6985
‑
6
8382
‑
7
9779
1
1
2104
1
2
3501
1
3
4898
1
4
6295
1
5
7692
1
6
8382
2. Ensure that there is sufficient play for the anchors.
Specifications/technical data
Pre-installation dimension (*)
= Finished installation
dimension (**) + 20-
25 mm
4.1.8.2
u
Array configuration on top of each
other
Note
In the case of roof batten clearances greater
than 460 mm, the 2-row and 3-row installations
are not possible. In this case, you can install the
2 or 3 rows individually (without using the same
central roof anchor).
Содержание auroTHERM VTK 1140/2
Страница 65: ...Technical data 10 0020077994_02 auroTHERM exclusive Installation manual 65 10 2 Dimensions 1652 111 702 ...
Страница 70: ......
Страница 71: ......