5 Operation
20
Instructions for use aroTHERM 0020151761_00
4.11
Setting the language
If you want to set another language:
▶
Press
and hold
and
at the same time
.
▶
Also press the fault clearance key for a short time.
▶
Press and hold
and
until the display shows the
language setting.
▶
Select the required language by pressing
or
.
▶
Press (OK) to confirm your selection.
▶
Once you have set the correct language, press (OK)
again to confirm this.
5
Operation
5.1
Switching the product on/off
▶
Use a partition with a contact opening of at least 3 mm
(e.g. fuses or power switches) to de-energise the product.
5.2
Activating frost protection
▶
To prevent the product from freezing, ensure that the
product is switched on.
5.3
Setting the target feed temperature in
heating mode
The actual target flow temperature is automatically determ-
ined by the system controller (you can find further information
about this in the operating instructions for the system control-
ler).
5.4
Setting a room thermostat or weather
compensator
2
1
▶
Set the room thermostat or the weather compensator
(1)
and thermostatic radiator valves
(2)
as specified in the
relevant instructions for these accessories.