COMMISSIONING
25
5.2.2
Connection options for current collectors
Flat plug connections, max. 25 A, d. h. > 25 A two flat
plug connections or one screw terminal (max. 50 A).
Electrical connection
X
Assembly
SA-BLS200S
Installation dimensions X
[mm] 48
Torque, connection [Nm] 18
Disconnected height X
[mm] approx. 58
Lift tolerance [mm] ± 5
Permissible wear [mm] 2
Electrical connection
Assembly
SA-BLS200Q
Installation dimensions X
[mm] 65
Torque, connection [Nm] 18
Disconnected height X
[mm] approx. 75
Lift tolerance [mm] ± 5
Permissible wear [mm] 2
Electrical connection
X
Assembly
SA-BLS100
Installation dimensions X
[mm] 40
Torque, connection [Nm] 5
Disconnected height X
[mm] approx. 51
Lift tolerance [mm] ± 5
Permissible wear [mm] 2
Electrical connection
Electrical connection
X
Assembly
SA-BLS50
Installation dimensions X
[mm] 38
Torque, connection [Nm] 2
Disconnected height X
[mm] approx. 44
Lift tolerance [mm] ± 4
Permissible wear [mm] 2
Electrical connection
X
Assembly
SA-BLS20
Installation dimensions X
[mm] 37
Torque, connection [Nm] 2
Disconnected height X
[mm] approx. 43
Lift tolerance [mm] + 3, - 2
Permissible wear [mm] 2