SMGM MODULES
44
6.8.2
Universal replacement unit: SMGM-RU
TIPS AND RECOMMENDATIONS!
SMGM-RU properties depend on how it is currently configured.
Note the description of the other modules!
The universal replacement unit can be used as a mobile or stationary module, depending on the configuration.
Connections
Description
X1 Logics supply
24 VDC ±10% / 500 mA
X3 Ethernet Port2
Ethernet interface 2
X4 Ethernet Port1
Ethernet interface 1
ANT1
SMGM/X coupler interface 1
ANT2
SMGM/X coupler interface 2
Parameters (depending on the SD card configuration)
Number of segments that can be supplied
1 /
2 (only SMGM system)
Number of device interfaces
1 / 2 / 4 / 15 /
30 [2x15] (only SMGM system)
Communication cycle
< 16 ms (8 ms ADV system)
SMGM Interface ANT1 & ANT2
Description
System connection
QLS - plug connection
Connection cable (HF cable)
Terminating resistor
An HF port ANT2 that is not used must be terminated
with the HF terminating resistor SMGM-XB-QLS-EA.