SAFETY INSTRUCTIONS
5
2
SAFETY INSTRUCTIONS
2.1
Safety
This section gives an overview of all important safety aspects relating to the protection of personnel as well as
the safe use and fault-free operation. Other, task-specific safety instructions can be found in the sections on
the individual phases of the product's life.
DANGER!
Failure to observe the safety instructions may result in risks to life and health!
2.2
Intended use
Intended use
The charge contacts are intended for charging moving shuttles which travel over the bar with the built-in cur-
rent collector.
• Ambient temperature: - 30°C to +55°C
• Air humidity: RH 95% (non-condensing)
• Service life of the charging contacts until replacement: 6 years
• Travel speed: Max. 4.0 m/s
• Acceleration: 1.0 m/s²
• Transitions/year: Approx. 1,000,000
• Voltage: 0 to 48VDC
• Max. current load: 40A, 60A peak
• Automatic shut-off of the charging current by the power supply units when raising or lowering the charging
contacts
• Only for indoor systems
• Length of the charging contact max. 5 m. Longer charging contacts on request
Foreseeable misuse
• Incorrect installation
• Insufficient air gap in relation to surrounding, possibly conductive parts
• Insufficient maintenance
• Temperature range exceeded