5
•
Close the inlet isolating valve and then
slow
ly open the ½” flushing valve to
relieve internal pressure.
•
Open the
1” blow off valve
•
Connect the ½” flushing valve to a
pressurized source of clean water using
the rubber hose provided with the
backflushing attachments.
•
Introduce flushing water until liquid runs
freely from the blow off valve.
•
Shut off and disconnect the supply of
clean water and close the blow off and
flushing valves.
•
Slowly open the inlet isolating valve. The
air release valve should exhaust air and
then close tightly
REPAIR KITS
Soft Goods Kit A927 (Part Number 2-80-11000-
008) contains Items 7, 8, 9 and 10
Linkage Kit AL927 (Part Number 2-80-11000-
084) contains Items 3, 5, 6, 8a, 11, 12, 13, 14,
15 and 20
Figure 927 Parts List
Item
Description
Standard Material
1
Body
Cast Iron
2
Cover
Cast Iron
3
Leverage Bracket
316 Stainless Steel
4
Orifice
316 Stainless Steel
5
Bracket Screw
304 Stainless Steel
6
Lock Washer
302 Stainless Steel
7
Orifice Button
Buna-N Rubber/SS
8
Hex Nut
304 Stainless Steel
8a
Hex Nut
304 Stainless Steel
9
Lock Washer
410 Stainless Steel
10
O-Ring
Buna-N Rubber
11
Lever Arm
316 Stainless Steel
12
Float Arm
316 Stainless Steel
13
Spring Pin
302 Stainless Steel
14
Valve Link
316 Stainless Steel
15
Universal Coupling
316 Stainless Steel
16
Cover Bolt
Zinc Plated Steel
17
½” Pipe Plug
Steel
18
1
” Pipe Plug
Cast Iron
19
2
” Pipe Plug
Cast Iron
20
Float Rod
316 Stainless Steel
21
Float Ball
316 Stainless Steel
22
Float Hood
316 Stainless Steel
23
Float Hood Bolt
Nylon
24
Connector
304 Stainless Steel
25
Lock Washer
410 Stainless Steel
REPLACEMENT PARTS
Genuine replacement parts are available from
your local VAG/GA Industries representative or
from the factory:
VAG USA, LLC
234 Clay Avenue
Mars, PA 16046 USA
Telephone: 724-776-1020
Fax: 724-776-1254
E-mail:
Please have the nameplate data available when
ordering parts.
WARRANTY
The Warranty for GA Industries valves is
included in our Terms and Conditions which can
be found here:
https://gaindustries.com/terms
Shown with optional flanged pipeline connection