20

 

 

7.3.8  Speed over ground (SOG) via NMEA0183 

A GPS signal can be connected to the SPU3 through the RS422 port (J4).  
The 

ship

’s speed over ground

 is hidden in the NMEA0183 protocol. The PEM4 + SPU3 system will read 

out the $--

VTG sentence (“speed over ground”) and the value will be displayed in knots.  

No adjustments are needed. ***) 
 

7.3.9  Speed through water (STW) via NMEA0183 

A GPS signal can be connected to the SPU3 through the RS422 port (J4). 
The 

ship

’s speed through water

 is hidden in the NMEA0183 protocol. The  PEM4 +  SPU3 system will 

read out the $--VBW 

sentence (“longitudinal water speed”) and the value will be displayed in knots. 

No adjustments are needed. ***) 
 

7.3.10  Speed through water (STW) via pulse signal from speed log 

In case the ship

’s speed is measured with a (Doppler) speed log, the pulse output signal from the speed 

log’s potential free contact is transmitted to the SPU3 through the speed log input (J6). 
The  ship

’s  speed  range is  programmed  at  VAF location  or  can  be set  via  the  settings  menu  by VAF 

authorised representatives through the PEM4 touch screen. 
The default setting is 200 pulses/nautical mile. ***) 
 

***) 

The  speed  which  is  displayed  and  used  for  calculations  is  depending  on  the  settings  and 

availability of the signal to the input.  
STW-NMEA is 1

st

 choice, STW-Speed log is 2

nd

 choice and SOG-NMEA is 3

rd

 choice. 


For example 

in the situation that “NMEA”, “NMEA STW” and “Speed log” are selected as “Enable” 

in the PEM4 settings menu and their signals are available on the inputs. In this situation the PEM4 
+ SPU3 system will use STW to display and use for calculations. In case the STW signal is not 
available, the PEM4 + SPU3 system will automatically use speed log. 

 

7.3.11  Density 

A  maximum  of  6  ViscoSense

®

3D  systems  can  be  connected  to  the  SPU3  system.  The  density  and 

temperature signals are connected to the SPU3 through analogue 4-20mA signals. 
Using density the mass flow and mass consumption can be calculated. 
 

7.3.12  Draft  

The draft front, middle SB, middle PS and at the back can be connected to the SPU3 through 3 analogue 
4-20mA signals. 
 

7.3.13  Inclino 

By use of an inclinometer the pitch, roll and yaw can be connected to the SPU3 through 3 analogue 4-
20mA signals. 
 
 
 

 
 

Note:  The  maximum  number  of  analogue  inputs  is  9  inputs,  depending  on  the  system 
configuration.

 

 

 

Содержание 667

Страница 1: ...Technical Manual Instructions for installation operation and maintenance Publication nr TIB 667 GB 1121 Supersedes TIB 667 GB 0918 667 PEM4 SPU3 SYSTEM For T Sense TT Sense and PT2 Flowmeters...

Страница 2: ...10 Analogue input for ViscoSense 3D Density temp and Viscosity 15 6 11 Modbus output to external system 16 6 12 Modbus connections 17 7 OPERATING PRINCIPLES 18 7 1 General 18 7 2 Displayed parameter...

Страница 3: ...REPAIR 44 10 TAKE OUT OF SERVICE 44 11 REMOVAL AND STORAGE OF EQUIPMENT 44 12 MALFUNCTION AND SEND FOR REPAIR 44 13 ENVIRONMENT 44 14 DISPOSAL 44 15 TROUBLE SHOOTING 45 16 EMC CLASSIFICATIONS OF THE...

Страница 4: ...sed to computer viruses since this could contaminate the micro SD card Contamination could disturb good working of the system For any additional information contact VAF Instruments B V Tel 31 78 618 3...

Страница 5: ...and display of the torque thrust shaft speed and power Calculation of the average shaft power shaft speed and torque during the last 1 4 and 24 hours Calculation of the total energy total revolutions...

Страница 6: ...gue input each Max 2 torque meters e g VAF Palco Torque speed power 3 analogue inputs each Max 6 auxiliary power Total auxiliary power 1 analogue input each Max 6 ViscoSense 3D Density Temperature and...

Страница 7: ...e PEM4 touch screen the IVY Propulsion Performance Management system or to a PC network on board max100m cable length Optional a RJ45 Ethernet switch for connecting e g a second PEM4 touch screen Figu...

Страница 8: ...box for at least one hour at the location where the system will be installed When the equipment is taken out of the box please leave the special protection supplied with the equipment as long as possi...

Страница 9: ...r connected equipment s should be checked and corrected 6 1 RECORD PEM4 SPU3 SYSTEM DATA This information is required when contact the supplier for any reason SPU3 nameplate Type No SPU3 Serial No Sup...

Страница 10: ...ted to the T Sense or TT Sense stator control box as shown in below figures Figure 2 Example of PEM4 7 SPU3 system including T Sense torque sensor and 2 Touch Screens Figure 3 Example of PEM4 8 SPU3 s...

Страница 11: ...to the SPU3 in accordance with drawing 0815 2019 in section 17 When available the second T TT Sense sensor cable needs to be connected as well 4 Connect the signal outputs of the flow meters speed log...

Страница 12: ...des information regarding flow meter TAG numbers configuration of the flow meters speed log or GPS at the SPU3 The number of backplanes differs per SPU3 configuration Figure 6 Example table Flowmeter...

Страница 13: ...IC 03 Power supply 115 230 VAC cable 3 x 1 5 mm2 IC 04 Modbus connection cable 1 x 2 x 0 50 mm2 twisted pair braid shielded IC 05 Flowmeter cable for pulse and PT100 3m integrated 2 x 3 x 0 50 mm2 or...

Страница 14: ...ORQUE SPEED AND POWER It is possible to connect a torque speed and power meter to the SPU3 system This torque speed and power meter needs to be equipped with analogue 4 20mA outputs The analogue 4 20m...

Страница 15: ...erator power level s Analog input Signal Type of input signal Terminal number on SPU3 Backplane X Shaft generator one 4 20mA active Terminal nr X1 and X2 Shaft generators two 4 20mA active Terminal nr...

Страница 16: ...number on SPU3 Auxiliary power 1 Modbus Terminal nr J1 see section 6 12 Auxiliary power 2 Modbus Terminal nr J2 see section 6 12 Auxiliary power Modbus Terminal nr J1 see section 6 12 6 10 ANALOGUE I...

Страница 17: ...ne Function code 3 Holding registers Modbus slave address 1 The Modbus output data is made available at two 16 bits integers which will have to be converted to 32 bits float according IEEE754 IEEE754...

Страница 18: ...placed at the first device SPU3 master and at the last connected device slave n Figure 10 Termination resistor switch The SPU3 termination resistor can be set by way of a jumper switch in on position...

Страница 19: ...o levels and access is only possible via a right of access code All setups and computations are stored in a battery backup RAM The PEM4 SPU3 system is self checking as for correct functioning of its m...

Страница 20: ...e rotor and control box For more detailed information see section 6 4 of TIB 661 T Sense or TIB 664 TT Sense 7 3 5 Shaft generator option The shaft generator output signal should be an active 4 20mA o...

Страница 21: ...h the PEM4 touch screen The default setting is 200 pulses nautical mile The speed which is displayed and used for calculations is depending on the settings and availability of the signal to the input...

Страница 22: ...ge when a new value is entered and the Go key is touched If you do not want to change the value touching the Go key again will close the numeric keypad and the touch screen will return to the previous...

Страница 23: ...s the main indicators for efficiency monitoring Figure 14 HOME menu The Engine menu is divided into 8 submenu s Consumption Average Consumption Total Consumption Accumulated Consumption Power Engine E...

Страница 24: ...The Alarms menu is divided in 3 submenus Current Alarms Alarm log Signals raw In the situation of an alarm due to an error in the system or for example too high fuel temperature an alarm message will...

Страница 25: ...m fuel density thermal expansion reference temperature Remain on Board ROB CO2 conversion factor caloric value water percentage and sulfer percentage of the fuel can be set MRV Cargo The amount of car...

Страница 26: ...kWh NM SFOC Specific Fuel Oil Consumption of the main engine g kWh Ship Efficiency Fuel consumption of the main propulsion engine s kg NM Twin screw propulsion When the PEM4 SPU3 system is monitoring...

Страница 27: ...el type Please be aware that after switching from kg hour to litres hour and vice versa the value at the accumulated fuel consumption counter is not correct The value at the Total Fuel consumption cou...

Страница 28: ...that by pushing the Reset buttons the values will be set to zero and the previous displayed values will be lost If you like to reset certain values and keep other values as they are you can select sp...

Страница 29: ...installation the information will be divided over four consecutive PEM4 screens The actual power is shown with different bars in the Shaft Power submenu Figure 28 The actual power and the average valu...

Страница 30: ...ase lubrication oil consumption is measured the PEM4 SPU3 system is able to calculate the SCOC value representing the Specific Cylinder Oil Consumption in g kWh Engine Efficiency Corrected submenu Fig...

Страница 31: ...n the Settings menu The white line can be displayed as an option and indicates a reference line which is for example the sea trial curve of the vessel The load limit lines make clear up to which torqu...

Страница 32: ...fficiency Operational Indicator EEOI value which is an indicator of the CO2 exhaust gas emissions per nautical mile per cargo load unit Ship Efficiency submenu Figure 37 Propulsion Ship Efficiency scr...

Страница 33: ...trials For more details see section 7 6 6 Environment submenu Figure 40 Environment screen EEOI TEU or EEOI DWT or EEOI PERSONS When fuel flow meters are incorporated in the PEM4 SPU3 system this scre...

Страница 34: ...ed and average torque values When Speed Over Ground SOG and Speed Through Water STW are measured simultaneously you will be able to judge if the vessel is sailing with or against the current Conning s...

Страница 35: ...12 temp sensor fail Faulty sensor or connection cable between SPU and meter Flowmeter 1 12 temp high Temperature high set point override T Sense 1 2 communication fail Modbus connection cable between...

Страница 36: ...f the fuel inside the specific flow meter This amount is not yet compensated for gravity change due to temperature deviations of the fuel Flow values will be converted to a reference temperature of 15...

Страница 37: ...dapting of Advanced settings should only be done by VAF authorised personnel or in cooperation with VAF authorised representatives The Settings menus is accessed through entering the specific code in...

Страница 38: ...ing temperature will select Fuel High Lower as switching temperature will select Fuel Low The different fuel types will be entered in the Fuel Type submenu Fuel Type Settings submenu Figure 57 Fuel Ty...

Страница 39: ...litre and vice versa As a standard the PEM4 SPU3 system monitors the fuel consumption per engine in kg hour In case you prefer to read out all fuel consumption data in litres hour you can change the m...

Страница 40: ...y The fuel oil specific gravity is a fixed or measured ViscoSense 3D value in the PEM4 SPU3 system The reference temperature 15 6 C default can be set per fuel type T Specific gravity at T temperature...

Страница 41: ...l sec 15 6 Specific gravity at reference temperature kg l t Specific gravity heated to a temperature kg l or Q F7 DT Temperature difference C gc Thermal expansion Gravity change C F8 DVtc Temperature...

Страница 42: ...t kg Dt Sample rate sec Specific Fuel Oil Consumption rate S F O C F13 SFOC Specific Fuel Oil Consumption g kWh G Mass flow rate to M E kg h P Shaft power kW Specific Fuel Oil Consumption Corrected ra...

Страница 43: ...e G Mass flow rate to M E kg h v Ship speed knots Thrust quotient F17 TQ Thrust quotient N kW T Thrust kN P Shaft power kW This quotient indicates the amount of thrust generated per MW propulsion powe...

Страница 44: ...v Ship speed Knots Specific Fuel CO2 Emission SFCO2 F23 SFCO2 Specific fuel CO2 emission per main engine g CO2 kW MCO2 Mass CO2 emission kg CO2 h P Shaft power kW Energy Efficiency Operational Indica...

Страница 45: ...4 SPU3 system are labelled correctly so that re installation of the PEM4 SPU3 system can be done without any errors Disconnect all the input and output wires Store the PEM4 SPU3 system in a box in a c...

Страница 46: ...Check all connections inside the temperature sensor Check the connections to the backplane in the SPU3 see section 17 Drawings Flowmeter alarms can occur when Flow meter 1 supply Flow meter 2 return...

Страница 47: ...TOUCH SCREEN 0815 1025 DIM DRAWING PEM4 8 TOUCH SCREEN 0815 2052 CONNECTIONS PEM4 8 TOUCH SCREEN 0815 1026 DIM DRAWING PEM4 10 TOUCH SCREEN 0815 2053 CONNECTIONS PEM4 10 TOUCH SCREEN 0815 2020 CONN DI...

Страница 48: ...47 Drawing 0815 1023 Dimensional Drawing PEM4 7 Touch Screen Drawing 0815 2025 Connection Drawing PEM4 7 Touch Screen...

Страница 49: ...48 Drawing 0815 1125 Dimensional Drawing PEM4 8 Touch Screen Drawing 0815 2052 Connection Drawing PEM4 8 Touch Screen...

Страница 50: ...49 Drawing 0815 1126 Dimensional Drawing PEM4 10 Touch Screen Drawing 0815 2053 Connection Drawing PEM4 10 Touch Screen...

Страница 51: ...50 Drawing 0815 2019 Sheet 1 of 3 Connection diagram T TT sense SPU 3 PEM4 x Drawing 0815 2019 Sheet 2 of 3 Connection diagram T TT sense SPU 3 PEM4 x...

Страница 52: ...51 Drawing 0815 2019 Sheet 3 of 3 Connection diagram T TT sense SPU 3 PEM4 x...

Страница 53: ...cific Fuel Oil Consumption SFOC Corr Specific Fuel Oil Consumption Corrected SI Syst me International d Unit s SPU3 Signal Processing Unit TFT Thin Film Transistor Liquid Crystal Display T Sense Optic...

Страница 54: ...ed installed All costs accruing above the single obligation described in the first sentence such as are not restricted to shipment costs travelling and accommodation costs or disassembly or assembly c...

Страница 55: ...product or allows it to be commenced then every agreement with regard to guarantee shall be void 6 Claims regarding defects must be submitted in writing as quickly as possible and not later than 14 d...

Страница 56: ...ware version 0 3 16 Section 17 Drawings updated Section 18 List of abbreviations updated Revision 0117 Section 3 analog input specs updated Section 6 6 and 6 7 updated with backplane X Section 6 8 6 9...

Отзывы: