background image

6

Installation - Quick guide

 7

 8

 9

1

2

3

5

1

2

3

5

4

7

Installation

Prepare the wall with 2 copper pipes 

at 147-153mm centres. Make sure the 

pipes are level 

(Fig. 1)

Connect the water supply to the 

inlet pipes. The hot water should be 

connected to the left hand pipe .
Before installing your new mixer, 

flush through the pipe work to ensure 

removal of debris, turn off the water 

supply. (Do not allow dirt, metal 

particles or shavings to block the filters 
fitted on inlets).

Temporarily place the valve over the 

copper pipes and mark the back of the 

body against the wall. 
There is a small amount of adjustment  

on the inlet pipes to allow fitting onto 

the copper pipes. Screw each side 

in or out as required, ensuring that 

both sides are screwed in equally & 

within the tolerance specified on the 

dimension page. 

Remove the valve 

(Fig. 2)

.

Remove the mounting plate from the 

back of the valve by releasing the two 

grub screws and pulling out the plate.
Place the mounting plate in the centre 

of the marked position and mark the 

two fixing holes.
Drill the marked holes to a suitable 

depth for the wall plugs and secure 

with supplied screws 

(Fig. 3)

.

If you are fitting the valve to a partition 

wall or a wall of particularly soft 

substrate you will need specialist fixings.

147-153mm

Mounting plate

Wall plugs

Screws

Fig. 1

Fig. 2

Fig. 3

Inlet pipe

20-25mm hole

Содержание WG-179M-CP

Страница 1: ...reference Installation Guide WG 179M CP Vado Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 aftersales vado com www vado com This instruction booklet covers these models WG 179M CP Version 1 1 8 17 where inspiration flows ...

Страница 2: ...r if there is any uncertainty Before making any inlet pipe connections all supply pipes MUST be thoroughly flushed to remove debris Failure to do so could result in damage or low flow from the mixer unit Water Supply Water Fittings Regulations 1999 Schedule 2 Section 13 The fitting of isolating valves to the inlet feeds is advised for ease of maintenance Please take great care when installing this...

Страница 3: ...4 Dimensions 124mm 147 153mm 118mm 22 5mm 48mm 40mm 5 Installation Quick guide 2 1 3 6 4 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 147 153mm 6mm ...

Страница 4: ...is a small amount of adjustment on the inlet pipes to allow fitting onto the copper pipes Screw each side in or out as required ensuring that both sides are screwed in equally within the tolerance specified on the dimension page Remove the valve Fig 2 Remove the mounting plate from the back of the valve by releasing the two grub screws and pulling out the plate Place the mounting plate in the cent...

Страница 5: ... mounting plate tighten both the nuts on the inlets being careful not to damage the plated surface Cover Olive Nut Shower hose connection Cold Hot 15mm copper pipe Mounting plate 15mm copper pipe Cover Olive Nut 9 Installation From the underside tighten both grub screws to secure the valve in position Hex key Shower hose Place a rubber washer into the nut end of the hose and attach it to the valve...

Страница 6: ...libration as follows Remove the temperature control handle see fig 1 Ensure the step on the stop ring is located at 4 o clock see fig 2 Do not remove the stop ring Turn the spline of the thermostatic valve clockwise to decrease the temperature and anti clockwise to increase the temperature until 38 C is achieved at outlet Note the sensing part of the thermometer probe must be fully submerged in th...