General installation

Operating Specifications

Important - please read

Operating Pressure

Minimum operating pressure

 0.2 bar

 

(

1 bar

 if used as a bath fill)

 

Maximum operating pressure

 5 bar

This fitting is a mixing device and therefore water supplies should be reasonably 

balanced.
When installed, the fitting must comply with the requirements of the Water Supply 

(Water Fittings) Regulations 1999 and Scottish Byelaws 2004. 

For further information, contact the Water Regulations department of your local water 

supplier (see the WRAS website www.wras.co.uk for details) or the Water Regulations 
Advisory Scheme by email (info

@

wras.co.uk) or telephone: 01495848454.

Before making any inlet pipe connections, all supply pipes MUST be thoroughly flushed 

to remove debris. Failure to do so could result in damage or low flow from the mixer 

unit.
The fitting of isolating valves to the inlet feeds is advised for ease of maintenance.
Please take great care when installing this mixer not to damage its surface.
Please note if installing in an enclosed environment, access should be left for servicing 

and maintenance. No costs relating to inadequate access can be accepted.

Contents of Packaging

Installation guide &  

User manual

3 handle, 3 outlet thermostatic 

shower valve

TAB-128/3WO-NO

T-CP

Keep for future reference

Installation Guide

NOTION

WHERE

INSPIRATION

FLOWS

NOTION

3 way, 3 outlet thermos

tatic shower valv

e

15

 ye

ar g

uarante

e

User Guide
Keep for future 

reference

Cover plate with  

Handset holder and outlet

Valve with 

Mortar guard

Handles with shrouds x 3

Содержание NOTION TAB-128/3WO-NOT-CP

Страница 1: ...ep for future reference Installation Guide NOTION where inspiration flows Vado Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 aftersales vado com www vado com This instruction booklet covers model TAB 128 3WO NOT CP Version 1 1 2 20 ...

Страница 2: ...1999 and Scottish Byelaws 2004 For further information contact the Water Regulations department of your local water supplier see the WRAS website www wras co uk for details or the Water Regulations Advisory Scheme by email info wras co uk or telephone 01495848454 Before making any inlet pipe connections all supply pipes MUST be thoroughly flushed to remove debris Failure to do so could result in d...

Страница 3: ...4 5 Contents of Packaging Shower hose with 2 washers Handset Adaptors to x 4 Dimensions 95mm 80mm 80mm 40mm 80mm 370mm 306mm 125 5mm 75 100mm ...

Страница 4: ...6 7 Installation Quick guide 1 2 77mm 263mm 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 3 90mm Installation Quick guide 4 5 1 2 1 2 1 2 1 2 3 x 1 x 3 ...

Страница 5: ...valve must be set into the wall between 75mm minimum 100mm maximum If you are fitting the valve to a partition wall or a wall of particularly soft substrate you will need specialist fixings Please contact VADO or retailer for WG STUDFAST C S S fixing Mortar guard During installation please leave the mortar guard secured to the valve to avoid damage to the product and protect the internals during t...

Страница 6: ...red channels e g outlet 1 to the shower head outlet 2 to the bath Note outlet 3 will be connected to the handset Mortar guard Mortar guard screws Cold Hot Outlet 2 Outlet 1 Handset outlet Installation Select the position for the shower valve and offer the shower valve to the wall make sure the valve is level and mark the 6 fixing points with a suitable pencil see above for dimensions Remove the sh...

Страница 7: ...er has slight adjustment Guide the handset holder onto the spigot first and then slide the cover plate over the shrouds Push the cover plate up to the wall and tighten the two grub screws on the underside of handset holder to secure it to the spigot Apply a thin bead of silicone around the outside to seal against the tiled surface Offset spline 13 Installation handset Handset outlet Place a rubber...

Страница 8: ... thermometer when the handle mark is located at 12 o clock NOTE temperature readings should be taken at normal flow rate after allowing for the system to stabilise 2 If the temperature is not 38 proceed to reset the calibration as follows Do not remove the plastic stop ring Turn the spline of the valve clockwise to decrease the temperature and anti clockwise to increase the temperature until 38 is...

Отзывы: