background image

Configuration and Administration

The TableMIC microphone typically does not require any setup when you connect it to Vaddio equipment.

It may require firmware updates from time to time, though. Additionally, you may wish to assign functions
to the microphone's Home button, to use it as a trigger devices for the Vaddio product to which you connect
it.

Configuring the Microphone's Home Button Behavior

The TableMIC microphone is a OneTouch trigger device for Vaddio conferencing products that have
EasyMIC ports and use macros. When the host device's OneTouch trigger is associated with a macro, you
can tap the microphone's Home button to execute the macro associated with the trigger – for example, if
the microphone is connected to a conferencing camera, the microphone's Home button can be configured
to return the connected camera to its home preset.

Note

The microphone's Home button behavior is configured in the host device's web interface.

If the host device's OneTouch trigger does not have a macro associated with it, the microphone's Home
button has no function. The button is illuminated whenever the microphone has power, whether it is
associated with a macro or not.

To configure the Home button's behavior:

1. Log in to the administrative web interface for the camera or other host device.

2. Write a macro that accomplishes what you want the device to do in response to the microphone's

Home button.

3. Associate the macro with the OneTouch trigger. If there is more than one OneTouch trigger, select the

one that corresponds to the EasyMIC port to which the microphone is connected.

Refer to the host device's manual for detailed information on working with macros and triggers.

Example scenario:

A TableMIC is connected to EasyMIC port 1 on a ConferenceSHOT AV camera. You want the camera to
point at the person at the far end of the table and zoom in for a head shot when you tap the microphone's
Home button. You want the same thing to happen when you press the Home button on the camera's IR
Remote Commander.

Use the camera's administrative web interface for this procedure.

Procedure:

1. Set up the camera shot you want and store it as the camera's Home preset.

2. Create a macro to move the camera to the home position.

3. Assign the macro to the OneTouch trigger that corresponds to the microphone.

Notes on this scenario:

n

If you connect more than one microphone to the same device, in step 4 you will need to set up all the
corresponding OneTouch triggers to make the Home buttons of all microphones behave the same way.

n

When the TableMIC microphone is connected to a camera, its Home button is off/on, not momentary.
In this situation, you can make it a dual-function button by assigning a macro to execute on enter (Home
button on) and one to execute on exit (Home button off).

Complete Manual for TableMIC Conference Room Microphones

5

Содержание TableMIC 1

Страница 1: ...Complete Manual for TableMIC Conference Room Microphones Document 411 0034 30 Rev B July 2019 ...

Страница 2: ...ic Connections 4 Configuration and Administration 5 Configuring the Microphone s Home Button Behavior 5 Updating Microphone Firmware 6 From ConferenceSHOT AV or AV Bridge MATRIX PRO 6 From EasyUSB Mixer Amp 8 Operation 11 Specifications 12 Troubleshooting 13 Use Storage and Care 13 Compliance and Conformity Statements 14 FCC Part 15 Compliance 14 ICES 003 Compliance 14 European Compliance 15 Warra...

Страница 3: ...400W North America 999 99950 401W Europe UK 999 99950 409W Australia New Zealand n ConferenceSHOT AV Bundle TableMIC 2 without speaker silver black 999 99950 600 North America 999 99950 601 Europe UK 999 99950 609 Australia New Zealand n ConferenceSHOT AV Bundle TableMIC 2 without speaker white 999 99950 600W North America 999 99950 601W Europe UK 999 99950 609W Australia New Zealand About this Ma...

Страница 4: ...rence n Mute button Mute the microphones in your conference room n Volume and Volume buttons Adjust the speaker volume in your conference room n Volume level indicator Display the current volume setting Cloth wrapped body Houses microphone elements positioned so that people seated at the conference table are centered in the area of maximum sensitivity Each microphone element provides integrated ec...

Страница 5: ...s helps maintain quality echo cancellation n Avoid contact with hockey sticks Don t Void Your Warranty Caution This product is for indoor use Do not install it outdoors or in a humid environment without the appropriate protective enclosure Do not allow it to come into contact with any liquid Do not install or operate this product if it has been dropped damaged or exposed to liquids If any of these...

Страница 6: ...ion Check your cables Connecting a cable to the wrong port or using the wrong pin out can result in equipment damage and will void the warranty Pro Tip Label all cables at both ends Basic Connections The TableMIC microphone connects to the EasyMIC port on Vaddio conferencing products using a standard Cat 5e or better cable up to 100 ft 30 m Note Cables with snag free boots are not recommended as t...

Страница 7: ...ccomplishes what you want the device to do in response to the microphone s Home button 3 Associate the macro with the OneTouch trigger If there is more than one OneTouch trigger select the one that corresponds to the EasyMIC port to which the microphone is connected Refer to the host device s manual for detailed information on working with macros and triggers Example scenario A TableMIC is connect...

Страница 8: ...te The filename ends in p7m 2 Open a browser and enter the host device s IP address to access its web interface o If the microphone is connected to a ConferenceSHOT AV point the remote at the camera and press the Data Screen button The camera s IP address is overlaid on the video outputs o If the microphone is connected to an AV Bridge MATRIX PRO use the knob on the front panel to dial to the Netw...

Страница 9: ...e to update 1 Navigate to the host device s System page and select the Peripherals or Microphones tab 2 Select the port connection for the microphone to be updated Complete Manual for TableMIC Conference Room Microphones 7 ...

Страница 10: ...ne s product page on the Vaddio website and download the update file identified as the serial firmware update The filename ends in ldr 2 Download the current version of the Vaddio Loader from support vaddio com or the Vaddio resources page at https www legrandav com en tools_and_training tools vaddio_tools Connect to a computer Connect the EasyUSB Mixer Amp to a PC as follows n Cat 5 cable from th...

Страница 11: ...ve selected the COM port to which it is connected If your query times out returns no response or returns a different response than expected contact Vaddio Technical Support to troubleshoot before proceeding 7 To confirm communication to the connected microphone and verify that it has not yet been updated to the latest version send a version inquiry command to the appropriate EasyMIC port EasyMic p...

Страница 12: ... flash the progress bar on the bottom starts to fill in and the microphone s mute indicator blinks The update takes a few minutes Caution Do not disconnect any cables until Vaddio Loader indicates a successful firmware load 4 When the Vaddio Loader displays the message Firmware Load and Install Successful the update is complete Repeat the process if you need to update another microphone Be sure to...

Страница 13: ...g functions n Home button Execute the associated OneTouch macro on the device to which the microphone is connected n Call button Connect to a Skype for Business conference or leave the conference n Mute button Mute the microphones in your conference room n Volume and Volume buttons Adjust the speaker volume in your conference room n Volume level indicator Display the current volume setting The con...

Страница 14: ...90 dB Environmental and Physical Operating Storage Temperature 32 F to 104 F 0 C to 40 C Operating Storage Humidity 10 to 80 non condensing Maximum Cabling Distance 100 ft 30 m Dimensions Height 1 43 in 3 6 cm Diameter 5 05 in 12 8 cm Complete Manual for TableMIC Conference Room Microphones 12 ...

Страница 15: ...s not work or behaves unpredictably The corresponding OneTouch trigger has not been set up on the connected device Set up the OneTouch trigger on the device connected to the microphone See Setting up the Microphone s Home Button Behavior The OneTouch trigger executes a macro that does not work properly For example if the macro uses the camera home command a home preset must be saved On the connect...

Страница 16: ...mful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may caus...

Страница 17: ...1000 4 4 2004 Corrigendum 2006 Electrical Fast Transients EN 61000 4 5 2006 Surge Immunity EN 61000 4 6 2009 Conducted Immunity EN 61000 4 8 2010 Power Frequency Magnetic Field EN 61000 4 11 2004 Voltage Dips Interrupts and Fluctuations KN22 2008 CISPR 22 2006 Conducted and Radiated Emissions KN24 2008 CISPR 24 1997 A1 2000 A2 2002 IT Immunity Characteristics EN 61000 4 2 Electrostatic Discharge E...

Страница 18: ...Support can be contacted by email at support vaddio com or by phone at one of the phone numbers listed on support vaddio com Return Material Authorization RMA number Before returning a product for repair or replacement request an RMA from Vaddio s technical support Provide the technician with a return phone number e mail address shipping address product serial numbers and original purchase order n...

Страница 19: ...n are subject to restocking charges n The Dealer has up to 60 days from the date of purchase to return Vaddio product for credit for future purchases of Vaddio product only n The Dealer has 61 to 90 days from the date of purchase to return Vaddio product with a 15 restocking fee or 50 00 fee whichever amount is greater n The Dealer has up to 30 days from the date of purchase to return OEM and othe...

Страница 20: ...y period will be repaired under the non warranty terms if o The equipment has been damaged by negligence accident act of God mishandling used with the incorrect modified or extended power supply or has not been operated in accordance with the procedures described in the operating and technical instructions o The equipment has been altered or repaired by other than the Manufacturer or an authorized...

Страница 21: ... the unit n Customers requesting an estimate on repair charges must do so up front when they call in for an RMA The RMA team will call or email with the estimate after evaluating the unit and before proceeding with the repair n Any product evaluated for a repair estimate is still subject to the minimum labor charges even if the customer decides not to proceed with the repair n Vaddio does not guar...

Страница 22: ...s Alexander Samokutyaev and Anton Shkaplerov By NASA https www flickr com photos nasa2explore 16166230844 Public Domain https commons wikimedia org w index php curid 38931301 European Space Agency astronaut Luca Parmitano Expedition 36 flight engineer outside the International Space Station By NASA http spaceflight nasa gov gallery images station crew 36 html iss036e016704 html Public Domain https...

Страница 23: ...ome button behavior defining 5 I ICES statement 14 installation typical 4 M macros 5 muting audio 11 O One Touch trigger 5 operating environment 3 13 P packing list 2 part numbers 1 2 performance specifications 12 precautions 3 for operating the system 3 product returns and repairs 16 R regulatory information 14 RJ 45 connectors 3 S software update 6 10 solving problems 13 storage environment 13 T...

Страница 24: ...pecifications drawings manuals technical support information and more 2019 Legrand AV Inc Vaddio is a registered trademark of Legrand AV Inc All other brand names or marks are used for identification purposes and are trademarks of their respective owners All patents are protected under existing designations Other patents pending Commercial AV Brands Chief Da Lite Middle Atlantic Projecta Vaddio ...

Отзывы: