background image

ProductionVIEW Precision Camera Controller 

 

ProductionVIEW Precision Camera Controller Manual 341-770 Rev H                          

Page 8 of 16 

The 3-Axis Joystick: 

Within the menus, the 3-axis joystick is programmable for pan, tilt and zoom direction control.  The zoom-in/zoom-
out, tilt-up/tilt-down and pan-left/pan-right commands can be inverted on all 3-axis to customize control of the PTZ 
cameras attached to Precision Camera Controller.   

   

LCD Screen:  

The LCD screen displays the menu structure, as well as information in real time as buttons are pressed, or 
buttons pushed on the controller.     

 

Note:  The LCD is covered with a thin protective film, please remove this film carefully.    
 
 

ProductionVIEW PRECISION CAMERA CONTROLLER Menu Structure  

The ProductionVIEW Precision Camera Controller has a back lit, 8-line 
LCD that displays the system menus.  The menus are traversed with the 
up and down arrows buttons, select and cancel buttons.  The menu 
structure is as follows: 
 

  

1

st

 Screen

 ProductionVIEW 

PC 

 

 

V01.00.0X (software version 0X) 

  Rescan 

Cameras 

  Cam 

Search 

Menu 

  Default 

Camera 

  Default 

Preset 

 

Rescan Cameras 

 >Select 

 

>Start - Rescans control ports 1 through 7 to find the cameras connected

 

 

Cam Search Menu

 

 

 >Select 

 

 

 

>All Ports:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 01:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 02:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 03:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 04:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 05:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 06:  (select search method – Auto, Sony, Canon, Panasonic) 

 

 

>Port 07:  (select search method – Auto, Sony, Canon, Panasonic) 

 

NOTE:  When using Panasonic cameras, it is necessary to select Panasonic to speed up the recognition of the cameras 
when ProductionVIEW HD is turned on.   

 
Default Camera 

(Automatic and Start-up Modes)

 

 >Select 

 

 

 

> 01 – 07 
Selects camera 1 through 7 as the default camera (default is 01) 

 

Default Preset

 (Automatic and Start-up Modes) 

 >Select 

 

 

 

> 01 – 14

 

 

 

Assigns camera preset 1 through 14 as Default Preset on the default camera (default is 01) 

 

CCU Mode

 

 

 >Select 

 

 

 

>All Ports:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 01:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 02:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 03:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 04:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 05:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 06:  (Select method – Direct Cam Ctrl or CCU) 

 

 

>Port 07:  (Select method – Direct Cam Ctrl or CCU) 

 

NOTE:  When Vaddio Quick-Connect CCUs are used with ProductionVIEW Precision Camera Controller, CCU mode 
disables the CCU functions on the Precision Camera Controller, allowing the user to control these functions from the 
Quick-Connect CCU) 

 

Menu 
Section 

Содержание PRODUCTIONVIEW

Страница 1: ...PRODUCTIONVIEW PRECISION CAMERA CONTROLLER Integration Joystick with Seven Discrete Camera Control Ports On board Camera Presets CCU Exposure and Color Control Functions with External Control Capability Part Number 999 5700 000 North America Part Number 999 5700 001 International Installation and User Guide ...

Страница 2: ...r Panel I O 5 First Time Set up with the ProductionVIEW Precision Camera Controller 5 Drawings System Configurations Examples 6 Operating the ProductionVIEW Precision Camera Controller 7 ProductionVIEW PRECISION CAMERA CONTROLLER Menu Structure 8 Compliance and CE Declaration of Conformity 11 Warranty Information 12 Appendix 1 13 RS 232 Control 13 Communication Specification 13 Female DB 9 Control...

Страница 3: ...e operating condition Important Safeguards Read and understand all instructions before using Do not operate any device if it has been dropped or damaged In this case a Vaddio technician must examine the product before operating To reduce the risk of electric shock do not immerse in water or other liquids and avoid extremely humid conditions Save These Instructions The information contained in this...

Страница 4: ...A Bus is default but is user definable Control codes for external video switchers and mixers can be programmed into the Precision Camera Controller for remote control of switcher functions on Control A and Control B buses menu selection 6 Camera Presets 14 presets are available for each PTZ camera connected 7 Joystick Controller The 3 axis Hall Effect joystick has been redesigned and is taller tha...

Страница 5: ...n 5 GND for use with external controllers or external production switchers 6 Tally Outputs For use with tally light or external devices i e video switchers camera control units etc These external control contacts correspond directly to front panel Control A B buses Tally contacts are latching TTL type These triggers are not relays and no voltage should be applied to these triggers at any time The ...

Страница 6: ...ors but only one operator can access the cameras at a time Cessna 172 not included Sample Configuration 3 Two Precision Camera Controllers set up in Link Mode Each Precision Camera Controller has 7 cameras connected and all cameras can be controlled from either Precision Camera Controller however not concurrently There can be two operators but only one operator can access all fourteen cameras at a...

Страница 7: ...on time Set this to the desired time for Edirol only 3 Turn off the ProductionVIEW Precision Camera Controller 4 Connect the external video switcher to the RS 232 Control Port DB 9 on the back of the Precision Camera Controller 5 Turn on the external switcher and let it boot up completely 6 Turn on the Precision Camera Controller and let it boot up completely making sure that it recognizes the ext...

Страница 8: ...ort 01 select search method Auto Sony Canon Panasonic Port 02 select search method Auto Sony Canon Panasonic Port 03 select search method Auto Sony Canon Panasonic Port 04 select search method Auto Sony Canon Panasonic Port 05 select search method Auto Sony Canon Panasonic Port 06 select search method Auto Sony Canon Panasonic Port 07 select search method Auto Sony Canon Panasonic NOTE When using ...

Страница 9: ...r Invert Port 07 Normal or Invert Return to Main Select Returns to Main Menu Zoom Direction Select Normal or Invert default is Normal Inverts the Joystick Zoom Direction Inverted Clockwise twist zoom out Camera Select Bus Select Control A Control B Assigns Control Bus A or B to select cameras for Pan Tilt Zoom control Preset Pan Speed Select 01 24 Sets the Pan Speed on all cameras between camera p...

Страница 10: ... Upon power up all cameras will go to Preset 14 Preset Location Local 6 InCam 8 Local In Local mode the ProductionVIEW stores all 14 presets internally In 6 InCam 8 Local mode the presets 1 through 6 will be stored in the cameras Presets 7 through 14 will be stored in the Precision Camera Controller Note The 6 InCam 8 Local mode allows for switching video sources when Sony cameras are moving to pr...

Страница 11: ... does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le minis...

Страница 12: ... and describe the reason for repairs or returns as well as the date of purchase and proof of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number on the outside of the box when returning the product All products returned for credit are subject to a restocking charge without exception Voided Warranty The warranty does not apply if the original s...

Страница 13: ...ogramming Language Firmware Version V01 01 XX Vaddio ProductionVIEW Precision Camera Controller This Menu System Access Power x Power On Off InCtlA x Control A 1 7 InCtlB x Control B 1 7 Camera x Switch to Camera 1 7 AWB x AutoWhiteBal On Off Preset x Go to Preset 1 14 BLC x BacklightComp On Off Store x Store Preset 1 14 Rescan Rescan cameras Joystick Pan Tilt Zoom JPanDir x x Port 0 7 Invert Norm...

Страница 14: ...alEcho SerialEcho On Off cr Serial Echo On Off SerialInfo SerialInfo On Off cr Serial Information mode on off SetDefault SetDefault 9 cr Set default Preset 1 12 Store Store 9 cr Store indicated preset on the current camera 1 12 Tally Tally High Low cr Non selected Idle tally level TiltSpeed TiltSpeed 9 cr Set Preset Tilt Speed Version Version cr Display System Version information Zoom Zoom in Out ...

Страница 15: ...ProductionVIEW Precision Camera Controller ProductionVIEW Precision Camera Controller Manual 341 770 Rev H Page 15 of 16 Inside Back Cover Blank ...

Страница 16: ...ddio com 2013 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice or obligation Vaddio ProductionVIEW Quick Connect WallVIEW EZCamera and PowerRite are registered trademarks of Vaddio All other trademarks are property of their respective owners Document Number 341 770 Rev H ...