Basic Connectivity Example of the HD-20 PTZ camera to a Vaddio Joystick Controller, Codec and Monitors:
Installation Basics:
Locate the camera mounting location paying close attention to camera viewing angles, lighting conditions,
possible line of site obstructions, and checking for in-wall obstructions where the camera is to be mounted. Pick a
mounting location that will optimize the performance of the camera.
RS-232 Cabling:
For RS-232, use a standard Cat-5e cable (568B termination for RJ-45 connectors) from the RS-232 port on the
back of a Vaddio ProductionVIEW camera controller or switcher. If the camera will be connected to a third-party
control system (such as AMX or Crestron), a DB-9 to RJ-45 adapter is supplied with the camera for RS-232.
Videoconferencing Codecs and RS-232:
Depending on the codec that is used, and which RS-232 port is used with a codec, special DB-9 to RJ-45
adapters may sometimes be required. Refer to Vaddio’s website, price list or on the ClearVIEW HD-20 web page
on specific diagrams for wiring the camera to videoconferencing codecs.
Rear of
ClearVIEW
HD-20
RS-232
YPbPr
12VDC, 3.0A
PowerRite
Power Supply
(Local)
HD Monitor (Simulated Video Feeds)
ProductionVIEW Precision Camera Controller
Other YPbPr FEED
HDMI
VC Codec
HDMI
Near End