background image

WallVIEW CCU 300 

WallVIEW CCU 300 Installation and User Guide 341-720 Rev. B                    

 

 

 

                Page 8 of 12 

FCC, ICES-003 Compliance and CE Declaration of Conformity  

For Vaddio Quick-Connect CCU and EZIM CCU products 

 
 
 

FCC Part 15 Compliance 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his/her own expense. 

Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This 
device must accept any interference including interference that may cause undesired operation of the device. 

Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void 
the user’s authority to operate this equipment. 

 

ICES-003 Compliance 

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set 
out in the Radio Interference Regulations of the Canadian Department of Communications.   

Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par 
le ministère des Communications du Canada. 

 

 

European Compliance 

This product has been evaluated for Electromagnetic Compatibility under the standards for Emissions and 
Immunity and meets the requirements for E4 environment.  This product complies with Class A (E4 
environment). In a domestic environment this product may cause radio interference in which case the user 
may be required to take adequate measures. 

Standard(s) To Which Conformity Is Declared: 

 

EMC Directive

 89/336/EEC 

EN 55022A

  

 

Conducted and Radiated Emissions 

EN 55024 

 

Electromagnetic Compatibility - Immunity

 

EN 61000-4-2

    

Electrostatic Discharge Requirements 

EN 61000-4-3

    

Radiated Electromagnetic Field Requirement 

EN 61000-4-4

    

Electrical Fast Transients / Burst Requirements 

EN 61000-4-5 

    

Surge Requirements 

EN 61000-4-6

   

Conducted Immunity Requirements 

EN 61000-4-8

   

Power Frequency Magnetic Field Requirements 

EN 61000-4-11

   

Voltage Dips, Interrupts and Fluctuations Requirements 

 
 

Содержание CCU 300

Страница 1: ...One Push White Balance and Auto Iris Like all Vaddio WallVIEW systems the Thin Profile Wall Mount and mounting hardware is included INTENDED USE Before installing the Vaddio WallVIEW CCU Camera System please read the entire manual thoroughly All Vaddio camera systems are designed for use indoors Outdoor operation is not recommended has not been tested and could damage the camera and or create a po...

Страница 2: ...al Wiring Diagram Example Figure 2 The Quick Connect CCU System uses a Cat 5 all 4 pairs for power to ensure the motors receive the required current to operate properly The Video Cat 5 cable uses all four pairs for video The RS 232 Cat 5 provides communication to the camera for CCU and PTZ control and G L where applicable to the camera These Cat 5 cables can be run up to 500 152 4m See Appendix 1 ...

Страница 3: ...rocessor memory When lit backlit blue SPDT switch the scene is activated To store a scene the user adjusts the camera to taste and touches and holds the scene button down until the button blinks Red Gain Control The Red Gain encoder adjusts the red gain of the signal when AWB is disengaged Blue Gain Control The Blue Gain encoder adjusts the blue gain of the signal when AWB is disengaged AWB The Au...

Страница 4: ...externally sync the cameras This input is transmitted through a differential amplifier to a receiver at the EZIM CCU The G L gain adjustment is on the EZIM CCU or the receive side of the signal Camera Feature Switches The QCCU interface has an 8 position dip switch on the rear panel to allow future functionality All switches should be in the down position Y Gain Adjusts Y Gain and allows the user ...

Страница 5: ...the performance of the camera Pre wire all cabling as required see wiring diagram examples The Thin Profile Wall Mount for the WallVIEW CCU 300 can be mounted directly to a 3 gang wall box or can be mounted to the drywall using four dry wall anchors MOUNTING INSTRUCTIONS Step 1 After determining the optimum location of the camera system mark locations for the four screw holes and cable pass thru v...

Страница 6: ...the standard connectors The basic system connectivity is illustrated in Figure 2 Note Plugging the POWER CAT 5 Cable into the wrong RJ 45 may cause damage to the camera system and void the warranty COMPLETING THE INSTALLATION Connect the Vaddio 36 VDC power supply to an AC outlet Power will travel down the Power CAT 5 cable to the cable shoe powering the camera The camera will Home to a centered p...

Страница 7: ...ed to camera EZIM Tally 2 Pin Phoenix type spring cage connector Video Inputs BNC Connector for Sync Video Outputs BNC Connectors for SD video Y C and Composite Video RJ 45 Transports video from camera EZIM Camera Select Switch For Future Use All switches should be in the down position Video Adjustments Y Gain luminance gain for fine tuning over longer cable distances Distance Compensation 100 200...

Страница 8: ...r s authority to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la classe A ...

Страница 9: ... Used 4 Not Used 5 Not Used 6 GND 7 RXD from TXD 8 TXD to RXD RS 232 G L OUT Connector RJ 45 Pin Signal RS 232 1 Not Used 2 Not Used 3 Not Used 4 G L 5 G L GND 6 GND 7 TXD to RXD 8 RXD from TXD Video Connector RJ 45 Pin Signal SD HD 1 CVBS CVBS 2 CVBS GND CVBS GND 3 Y Y 4 C PB 5 C GND PB GND 6 Y GND Y GND 7 Not Used PR 8 Not Used PR 12345678 12345678 12345678 12345678 300 200 POWER 36V 2 78A 100 4...

Страница 10: ...D 3 Y Y 4 C PB 5 C GND PB GND 6 Y GND Y GND 7 Not Used PR 8 Not Used PR DB 25 Connector Pins Signal 1 CVBS GND 14 CVBS 2 G L GND 15 G L 3 NC 16 GND IN 4 TXD IN 17 RXD IN 5 NC 18 NC 6 NC 19 NC 7 GND PR 20 PR 8 GND C PB 21 C PB 9 GND Y Y 22 Y Y 10 GND PWR 23 GND PWR 11 GND PWR 24 12V PWR 12 12V PWR 25 12V PWR 13 12V PWR 12345678 12345678 12345678 POWER EZIM CCU VIDEO G L GAIN RS 232 IN G L IN Genloc...

Страница 11: ...nd describe the reason for repairs or returns as well as the date of purchase and proof of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number on the shipping label of the box when returning the product Please see Vaddio s website for current RMA policies and procedures Voided warranty The warranty does not apply if the original serial number ...

Страница 12: ... 971 4464 www vaddio com 2008 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing subject to change Vaddio WallVIEW HSDS Quick Connect EZIM ProductionVIEW PreVIEW EZCamera and PowerRite are registered trademarks of Vaddio All other trademarks are property of their respective owners Document Number 341 720 Rev B ...