background image

 Quick-Connect USB Interface 

 
 
 

Quick-Connect USB, Document Number 342-0653 Rev. B    

 

Page 15 of 36 

 

3)  Pan/Tilt and Zoom Speed Controls:  

The speed for both the Pan/Tilt and Zoom controls can be adjusted 

with the two (2) buttons in this section.  For tighter shots, it is recommended that the slower speed is used.

 

Note:

  Speed control does not apply for the WideSHOT and zoom speed only applies to the PowerVIEW, 

ClearVIEW and ZoomSHOT.

 

 
4)  Store Preset Button:  

Clicking the Store button opens up a Store Preset pop-up dialog box.  To set presets, 

set up the camera shot, click on choice of preset number (1 through 6).  The preset is stored and the dialog 
box closes.

 

 

5)  Camera Presets:  

Six (6) presets can be recalled simply by clicking a preset number. 

 
6)  CCU Scenes:  

The user has access to the CCU scenes set and stored by the Admin.  There are three (3) 

user definable presets and six (6) presets preconfigured by the technical folks at Vaddio (really Scott set them 
all) that are meant to be used in certain lighting scenarios.  These lighting presets included:  Automatic, 
Incandescent Hi, Incandescent Lo, Fluorescent Hi, Fluorescent Lo and Outdoor. 

 

7)  Administration Menu:  

By clicking on the Administration menu bar, the Admin Login screen will appear.  The 

default Admin password is:  password

 

 

8) Vertical: 

 

The vertical button will reduce the size of the window for 

the user controls and remove the menu tabs on the left side of the 
screen.  The vertical sizing works well when using it with a soft-client 
codec.  Click on ‘Full’ for full screen size camera control web pages.  

 

 

 

 
 
 
 
 
 
 
 

 
Screen Shot:  Admin Log-in 

By selecting the Admin Menu Bar, the Admin Login password pop-up window will appear and await the entry of 
the password.  By entering the Admin menus, 10 more menu keys appear on the left side of the screen.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Default: 

Admin Account 
Password is:  
password 

Image: 

Reduced window size 
for camera control to be 
used while a UC 
application is open 

Содержание 999-1105-038

Страница 1: ...uick Connect USB Interface for use with Vaddio Cameras with EZCamera Cat 5 interface featuring Multi format Outputs and IP or USB Streaming Model Number 999 1105 038 North America Model Number 999 1105 138 International Installation and User Guide Images Quick Connect USB Front Panel ISO above and Rear Panel ISO below ...

Страница 2: ...Quick Connect USB Interface Quick Connect USB Document Number 342 0653 Rev B Page 2 of 36 Inside Front Cover Blank ...

Страница 3: ... USB Web Pages Tour 13 Screen Shot Login 13 Screen Shot Camera Control Page No Camera Detected 14 Screen Shot User Menu Camera Control Page 14 Screen Shot Admin Log in 15 Screen Shot Admin Menu Camera Settings Page 16 Screen Shot Admin Menu USB 2 0 or IP Streaming Mode Page 18 Screen Shot Admin Menu Room Labels 18 Screen Shot Admin Menu DHCP Network Configuration 20 Screen Shot Admin Menu Static I...

Страница 4: ...ble UC client using UVC drivers can be used see compatible UC program list The system also streams IP video H 264 and supports both RTSP and HLS HTTP Live Streaming Apple s variant on HTTP streaming An embedded web server provides for browser based access of robotic camera controls camera presets and rudimentary CCU functions color and shading painting controls as well as the video configuration w...

Страница 5: ...ord Documentation COMPATIBLE VADDIO CAMERAS Table Quick Connect USB Interface and Vaddio Camera Compatibility Camera Model Base Camera Model Number Notes ClearVIEW HD 18 998 6900 000 Full Compatibility ClearVIEW HD 19 998 6940 000 Full Compatibility ClearVIEW HD 20 998 6950 000 Image controls not fully implemented PowerVIEW HD 22 998 6860 000 Full Compatibility PowerVIEW HD 30 998 6970 000 Full Co...

Страница 6: ...top or tablet users of UC conference systems Upon power up or power reset this display will indicate when the unit is in initialization mode 2 Power System Reset Switch The System Reset switch on the front panel is a blue back lit tactile switch that will illuminate when power is present at the rear power connector Pressing in and holding this switch for 1 15643 seconds will restart reinitialize t...

Страница 7: ...the back of the camera The YPbPr output resolution will be the same as the HDMI output resolution SD video resolutions Y C and CVBS formats are not supported by the Quick Connect USB Interface however some progressive frame analog component SD video is supported 7 HDMI Output The digital video output on the HDMI connector can either be YCbCr color space normal HDMI mode or can be changed to DVI D ...

Страница 8: ...ideo EZ POWER VIDEO 24VDC 2 0 A Power Supply HD Monitor Simulated HD Video Feed ProductionVIEW Precision Camera Controller Note RS 232 can be run directly to the camera or through the Quick Connect USB in this configuration HD Video HSDS differential Power PowerVIEW HD 22 PTZ Camera Rear View RS 232 Control HDMI Video HD Video YPbPr HDMI YPbPr Notes Same Subject Resolution Determined by camera Sim...

Страница 9: ...ation Two Cat 5 Cables up to 150 45 72m for stationary POV cameras such as ZoomSHOT and WideSHOT ClearVIEW HD 19 HD Camera PC with Browser for Control Network Client Video Ethernet Network Power to Camera HD Video to QC USB IP H 264 Streaming RTSP or HLS Ethernet Two 2 Cat 5 Cables carry Power Video and Control Signals HDMI Video Monitor Simulated Video Feed USB 2 0 Cable Quick Connect USB Interfa...

Страница 10: ...cells Cameras generally don t like to be swamped with fluorescent light and nobody sits on the ceiling anyway For Power Video and RS 232 signals use standard Cat 5 cable 568B termination and real RJ 45 connectors from the EZ POWER VIDEO and RS 232 ports on the back of the cameras to the Quick Connect USB Interface All WallVIEW Systems include a wall mount with mounting hardware For new installatio...

Страница 11: ...a few seconds differential HD video will travel back down the Cat 5 cable to the Quick Connect USB When an image is available the camera is ready to accept control information from the IR remote control or RS 232 camera controller however it is always best to choose and use IR or RS 232 and not both concurrently If connected to the Network the Quick Connect USB will display the Hardware HW MAC Add...

Страница 12: ...P with H 264 video are compatible with the industry leading PC media players Quick Time 10 2 VLC Media Player 2 0 4 Real Player 16 0 Compatibility Operating Systems Apple OS X 10 7 and above Windows XP w Service Pack 3 with known issues and errata Windows 7 Linux Evolving Compatibilities As more UC soft client and lecture capture programs are released and gain popularity Vaddio will provide a cont...

Страница 13: ...g on the age of the computer you may not need a cross over cable Either way the steps are the same for network or direct connection to a computer The default address of the QC USB camera is 169 254 1 1 and the Subnet mask is 255 255 0 0 Different computer OS types all have their own way of doing things without question but they are essentially doing the same stuff changing the IP address so the we...

Страница 14: ...f initialization Screen Shot User Menu Camera Control Page 1 Pan Tilt and Home Controls These intuitive controls use the up down arrows for camera tilt the left right arrows for camera pan and the center button to move the camera to the home position These controls are not functional with the ZoomSHOT or WideSHOT cameras 2 Zoom Control The camera s zoom lens can be controlled with the to zoom in a...

Страница 15: ...ts and six 6 presets preconfigured by the technical folks at Vaddio really Scott set them all that are meant to be used in certain lighting scenarios These lighting presets included Automatic Incandescent Hi Incandescent Lo Fluorescent Hi Fluorescent Lo and Outdoor 7 Administration Menu By clicking on the Administration menu bar the Admin Login screen will appear The default Admin password is pass...

Страница 16: ... camera when the camera powers up The pull down menu will allow the selection of one of the 6 factory scenes or any of the 3 User defined scenes 3 CCU Scenes Click on any of these 9 buttons to load one of the CCU scenes into the camera These Scenes can be fine tuned if changes are needed and stored into any of the three User defined scenes 4 Color Settings When painting or shading camera scenes fo...

Страница 17: ... Back Light Compensation will be applied to the camera if BLC is supported by the camera and the camera is in Auto White Balance mode Detail Move the adjustment slider as required for amount of detail Aperture desired A numeric value will be displayed in the box to the right of the slider Note If the detail is too high the video can look grainy and appear noisy too Chroma Move the adjustment slide...

Страница 18: ...the colors are more vibrant and precise 4 IP Streaming Settings The Video Settings allow the selection of the target performance for the IP Streaming The QC USB is set up for a variable bit rate and the user can select the video resolution and the quality such as High Quality Best Standard Quality Better and Low Bandwidth Good Every effort to eliminate stupefyingly bad combinations with the 5 or 6...

Страница 19: ...19 of 36 Screen Shot Admin Menu Room Labels The Room Labels menu allows the administrator to label the company name room name room phone and help phone on a per QC USB basis The labels appear on every page at the top middle of the page Simply enter the room information and click Save ...

Страница 20: ...ere the Network administrator assigns either DHCP or a Static address and the associated parameters Screen Shot Admin Menu Static IP Configuration If Static IP is used the IP Address Subnet Mask and Gateway are manually entered Click on Save to keep the Static IP information MAC Address IP Address Subnet Mask and Gateway will Auto fill when in DHCP Mode IP Address Subnet Mask and Gateway are enter...

Страница 21: ...word is also password The Network administrator can reassign the user name and password as well as the Admin password There is only one user password and one admin password at any given time If changes are made click on Save to store the change Screen Shot Admin Menu Diagnostics Diagnostics menu button will display a set of self diagnostics These diagnostics may help the Vaddio technical support t...

Страница 22: ...e update is chosen in this menu and the update is started here too A remote system Reboot and Restore to Factory Presets is also available Screen Shot Admin Menu Update Confirmation After clicking on Begin Firmware Update a confirmation pop up and warning will be displayed Please contact Vaddio Tech support for assistance with updates Please read and completely understand the pop up warnings as it...

Страница 23: ... please don t interrupt the firmware load this example is from 1 0 0 to 1 1 0 Screen Shot Admin Menu HELP Service Help information can be found under the Help menu Support phone numbers and e mail manuals FAQ s and System information is listed on this page Have this page open when calling Vaddio Tech Support TECHNICAL SUPPORT NOTE Please work with your Network Administrator prior to calling Vaddio...

Страница 24: ...d Vaddio IR Remote Commander or through IP as described earlier through the QC USB s web pages Make a test call to ensure the system is working properly VLC Media Player Example 1 Same first step as above 2 Open VLC Media Player and perform the following steps a Click on the Media menu and drop down to Open Capture Device and click it b Under Device Name go to the Video Device Name drop down and c...

Страница 25: ...rential HD Video Dip Switches 5 Position Color Space Updating and Future Use H 264 Resolutions CIF 640x480 VGA 480p 720p 30 1080p 30 1080p Ethernet only Front Panel 20 x 2 line Character Negative Mode LCD Displays MAC HW for Hardware and IP Address Power System Reset Tactile flush mount Back lit Switch Network LED Indicates connectivity and activity USB LED Indicates Streaming Mode Supported Media...

Страница 26: ... expressly approved by Vaddio can affect emission compliance and could void the user s authority to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioéle...

Страница 27: ...technical support Provide the technician with a return phone number e mail address shipping address product serial numbers and original purchase order number Describe the reason for repairs or returns as well as the date of purchase See the General RMA Terms and Procedures section for more information RMA s are valid for 30 days and will be issued to Vaddio dealers only End users must return produ...

Страница 28: ...th QC USB Pin 6 Digital GND Pin 7 RXD from TXD of control source Pin 8 TXD to RXD of control source Table Quick Connect USB DE 15 Pin Output Analog Component YPbPr COMMUNICATION SPECIFICATION Communication Speed 9600 bps default Start bit 1 Stop bit 1 Data bits 8 Parity None No Flow control Pin Signal 1 Power 2 Power 3 Y 4 PB 5 PB 6 Y 7 PR 8 PR Pin YPbPr 1 Pr 2 Y 3 Pb 4 5 6 Pr GND 7 Y GND 8 Pb GND...

Страница 29: ... Example COMMAND stream mode get RESPONSE streaming mode usb Syntax Error Example COMMAND camera pan right RESPONSE ERROR Additional programming controls associated with the terminal protocol includes CTRL 5 Clears the current serial buffer on the device Telnet sessions will require access verification and uses the same username and password associated with the Administrator account on the embedde...

Страница 30: ...camera up down Move the camera down stop Stop the camera movement speed Optional integer from 1 20 that represents the speed Default 10 EXAMPLES camera tilt up Tilts the camera up at the default speed camera tilt down 20 Tilts the camera up using a speed of 20 camera tilt stop Stops the tilt movement of the camera Camera Zoom NAME camera zoom Zoom the camera in or out SYNOPSIS camera zoom in out s...

Страница 31: ...plete line is read Listed below are examples of history expansion Substitute the last command line N Substitute the Nth command line absolute as per history command N Substitute the command line entered N lines before relative EXAMPLES history Displays the current command buffer history 5 Sets the history command buffer to remember the last 5 unique entries Network Ping NAME network ping send ICMP...

Страница 32: ...ings get ping count count size size destination ip DESCRIPTION Method used to get the current network settings or check network OPTIONS settings Get the current network settings ping Send ICMP ECHO_REQUEST to network host EXAMPLES network settings get Gets the current network settings network ping count 1 10 10 10 100 Pings 10 10 10 100 once and displays results Streaming Mode NAME streaming mode ...

Страница 33: ... streaming resolution 1080p Set video resolution to 1080p 720p Set video resolution to 720p 4cif Set video resolution to 4cif 480p Set video resolution to 480p cif Set video resolution to cif EXAMPLES streaming resolution get resolution 720p Returns the current streaming resolution streaming resolution 720p OK Sets the streaming resolution to 720p Streaming NAME streaming Gets or sets the current ...

Страница 34: ...ardware Hardware reset is designated by rear panel dip switches in down position off Returns the factory reset status system factory reset on factory reset software on factory reset hardware off Enables factory reset upon reboot System Reboot NAME system reboot Reboots system SYNOPSIS system reboot seconds DESCRIPTION Method used to reboot system OPTIONS seconds The number of seconds to delay the ...

Страница 35: ...Quick Connect USB Interface Quick Connect USB System Document Number 342 0653 Rev B Page 35 of 36 Inside Back Cover Blank ...

Страница 36: ...Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to change without notice or obligation Vaddio PowerVIEW ClearVIEW ZoomSHOT WideSHOT REVEAL CeilingVIEW ProductionVIEW WallVIEW EZCamera Quick Connect and HSDS are trademarks of Vaddio All other trademarks are property of their respective owners Document Number 342 0653 Rev B ...

Отзывы:

Похожие инструкции для 999-1105-038