TROUBLE SHOOTING GUIDE
Symptom
Cause
Remedy
The motor will not start, no water is pumped
No electricity
Ensure that the pump is connected to a live
outlet
Motor protection tripped
Verify the cause and reset the switch. If the
thermal circuit breaker has tripped wait for the
system to cool down
Defective condenser
Replace the condenser
Shaft blocked
Verify the cause and unblock the pump
The motor runs but no water is pumped
The pump is sucking air
Makes sure that the joints are airtight
Check that the level of liquid has not dropped
below the minimum priming level.
The pump rotates in the wrong direction
Reset the direction of rotation
The pump stops after running for a short pe-
riod of time because the thermal motor circuit
breaker trips
The power supply does not conform with the
data on the nameplate
Check the voltage on the power supply cable
leads
A solid object is blocking the impellers
Call 1800 032 566 for your nearest Reece
branch
The liquid is too thick
Call 1800 032 566 for your nearest Reece
branch. You may need a different type of
pump
VADA - V110-H
Liquid may be HOT, release pressure with care
before servicing.
Pump should only be serviced by qualified
personnel. For best results, use only genuine ser-
vice parts. Be sure to prime pump before starting.
To avoid dangerous or fatal electrical shock hazard,
turn OFF power to motor and remove plug from
power outlet before working on pump or motor.
SERVICE AND MAINTENANCE
GENERAL CARE AND MAINTENANCE
Under normal conditions VADA pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically
check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of
abnormal mechanical friction in the pump and/or motor.
If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place.