background image

•  Built to handle clean and greywater with soft solids up to 15mm (no suspended solids like stones, 

pebbles, mulch or abrasive material such as sand, cement, dust or harsh detergents)

•  Optimum operating range: 4.3–3.2 metres head, 64–96 litres per minute

•  Max water temperature: 40°C

•  Max submersion depth: 6m

•  IP Rating: IP68

•  1PH, 230VAC ±10%, 50 Hz, (P1) 350W, (P2) 180W, Run current 1.75 A

PIT SIZE

The Vada V150 requires a minimum pit size of 450mm (L) x 450mm (W) x 510mm (H) to ensure the 
float can rise.

If your pit is tapered, ensure the float can be fully engaged without getting caught on the pit wall.

HELPFUL HINT

5

4

VADA 

SUMP PUMP

 

V150 

INSTALLATION MANUAL

KNOW YOUR PRODUCT

SPECIFICATIONS

Constructed from cast iron for durability and designed with a vortex impeller for improved water flow 
and reduced clogging. This pump is built to handle clean and greywater and soft solids up to 15mm 
O.D. at a 10% content or fine solids at 1% concentration. The sump pump is supplied as standard 
with a 10m power cable length and connections to suit 32mm, 25mm and 20mm hose. 

Note: 

A larger diameter hose or pipe will offer less resistance to flow and will give better performance.

Discharge outlet  
connection 32mm BSP FI

Suction inlet

10m Power cable

Standard float with automatic 
switch operation

Cast iron pump housing

Internal vortex impeller

510mm H

450mm L

450mm W

300mm

290mm

Содержание SUMP PUMP V150

Страница 1: ...SUMP PUMP INSTALLATION MANUAL V150...

Страница 2: ...number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simple install...

Страница 3: ...t wall HELPFUL HINT 5 4 VADA SUMP PUMP V150 INSTALLATION MANUAL KNOW YOUR PRODUCT SPECIFICATIONS Constructed from cast iron for durability and designed with a vortex impeller for improved water flow a...

Страница 4: ...olids larger than maximum recommended particle size 15mm Pumping liquid containing abrasive solids stones ceramics etc What you ll need to supply The residence must also have a Residual Current Device...

Страница 5: ...charge pipework Ensure you have selected the position for your discharge outlet on the pit cut a hole to size on the pit and then secure a tank outlet or similar Note The length and the diameter of th...

Страница 6: ...upply cord is supported by the delivery pipes at 3 metre intervals 2 Ensure the powerpoint is in a dry and flood free location 3 Plug the power supply cord into the 10 Amp powerpoint Do not switch on...

Страница 7: ...friction in the pump and or motor which may be caused by debris caught in the impeller CHECKING THE FLOW 1 Get a bucket of a known size e g 10 litre bucket and place it near the Sump Pump 2 Get a hose...

Страница 8: ...uct lifespan Note Should you require further specific information or assistance with calculating the system duty of your application please contact your local Reece branch STORING THE PUMP PRODUCT DIM...

Страница 9: ...t the float operation is not impaired Physically lift the float switch vertically if needed The float is caught on something and cannot rise Ensure that the float can move freely Ensure the pit size i...

Страница 10: ...g used with clean and grey water and is NOT being used with alternative fluids specifically abrasive corrosive or explosive fluids The pump is isolated from electrical supply during installation and a...