background image

 page 1 of 152

Speed controlled chemistry diaphragm pumps

and chemistry pumping units

Instructions for use

Technology for Vacuum Systems

 ME 16C NT VARIO

MV 10C NT VARIO

 MD 12C NT VARIO

PC 3010 NT VARIO

 PC 3012 NT VARIO

PC 3012 NT VARIO + EK Peltronic

 PC 3016 NT VARIO

Part I of II

Part I

Part I: 

Safety information - 

Technical data - 

Use and operation

Содержание MV 10C NT VARIO o.C.

Страница 1: ...umping units Instructions for use Technology for Vacuum Systems ME 16C NT VARIO MV 10C NT VARIO MD 12C NT VARIO PC 3010 NT VARIO PC 3012 NT VARIO PC 3012 NT VARIO EK Peltronic PC 3016 NT VARIO Part I...

Страница 2: ...phragm pump before leaving our factory is tested intensively including an endurance run of 14 hours Any faults even those which oc cur rarely are identified and can be eliminated immediately After com...

Страница 3: ...equired measures must be applied Safety instructions for vacuum equipment FR Attention Le mode d emploi pr sent n est pas disponible dans toutes les langues d Union Europ enne L utilisateur ne doit me...

Страница 4: ...tiende este manual En este caso se debe disponer de una traducci n t cnicamente correcta del manual completo El manual debe ser le do y entendido completamente y deben aplicarse todas las medidas de s...

Страница 5: ...ente letto e compreso prima di operare con lo strumento e devono essere applicati tutti gli accorgimenti richiesti Istruzioni di sicurezza per apparecchi a vuoto JP KR LT D mesio is vadovas n ra patei...

Страница 6: ...o ci przeczytana i zrozumiana przed podj ciem pracy z urz dzeniem oraz nale y podj wszystkie niezb dne kroki zwi zane z prawid owym uzytkowaniem Wskaz wki bezpiecze stwa do urz dze pr niowych PT Aten...

Страница 7: ...opravljene pa moraja biti tudi vse potrebne meritve Varnostni nasveti za vakuumske naprave SK Upozornenie Tento manu l nie je k dispoz cii vo v etk ch jazykoch E U vate nesmie obsluhova zariadenie po...

Страница 8: ...ion 1 switch off 2 press both 3 turn 4 press Portugu ycc Polski Nederl Suomi CVC 3000 V2 0 Deutsch English Fran ais Italiano Espa ol T rk e Portugu ycc Polski Nederl Suomi CVC 3000 V2 0 Deutsch Englis...

Страница 9: ...s 26 Gas inlet temperatures 29 Wetted parts 31 Abbreviations 32 Pump parts 32 Use and operation 36 Installation 36 Vacuum connection inlet 37 Separator AK at the inlet 38 Connecting the outlet 39 Exha...

Страница 10: ...Setting of the interface 84 Read commands CVC 2000 85 Write commands CVC 2000 86 Read commands CVC 3000 88 Write commands CVC 3000 90 Accessories Spare parts 93 Troubleshooting 96 Replacing the device...

Страница 11: ...rs arising from the pump and the pumped substances VACUUBRAND disclaims any liability for inappropri ate use of these pumps and for damage from failure to follow instructions contained in this manual...

Страница 12: ...d to address practices not related to personal injury Caution Hot surface Disconnect equipment from AC power Dispose of electronic equipment according to regula tions NOTICE Formatting used in this ma...

Страница 13: ...hose deficiencies Replace the protective caps if the equipment is not used immediately Store the equipment in dry and non corrosive conditions see also Technical data pg 26 Do not use any damaged equi...

Страница 14: ...Do not pump liquids Ensure that the pump is chemically resistant to the pumped substances prior to operation Use the equipment only as intended that is for genera tion measurement and control of vacu...

Страница 15: ...ump without any me chanical contact other than the pump feet Comply with maximum permissible pressures at in let and outlet and with maximum permissible pres sure differences between inlet and outlet...

Страница 16: ...larly for dust dirt Clean fan guard grills if necessary to avoid a reduction of ventilation Position the CVC 3000 controller and its vacuum line in such a way that condensate cannot flow towards the p...

Страница 17: ...mity with regard to design type and model Directive EN 61010 1 gives in detail the conditions under which the equipment can be operated safely see also IP degree of protection Technical data pg 26 Ope...

Страница 18: ...may lead to increased temperatures even to the point of exceeding the maximum permitted temperatures Check the inlet and outlet of the pump if there is a danger of forming deposits inside the pump e g...

Страница 19: ...r otherwise remove any poten tially explosive mixtures at the outlet of the pump or dilute them to non explosive concentrations Never operate this pump if it has a damaged cord or plug If the pump is...

Страница 20: ...d into the environment or into the pump housing or motor Comply with all notes regarding proper use of the pumps as well as operation and maintenance guid ance The residual leak rate of the equipment...

Страница 21: ...f the pump do not cause burns Provide a suitable contact guard if necessary Ensure that the coolant outlet pipe at the waste vapor condenser is always free and that it cannot get blocked Prevent the b...

Страница 22: ...om In normal use the lifetime of the diaphragms and valves is typically 15 000 operating hours Bearings have a typi cal durability of 40000 h Ensure that the pump cannot be operated acciden tally Neve...

Страница 23: ...nents from the vacuum system Allow sufficient cooling of the pump Drain condensate if applicable Ensure that maintenance is done only by suitably trained and supervised technicians Ensure that the mai...

Страница 24: ...which during normal operation explosive atmo spheres caused by gases vapors or mists normally don t occur or if they do occur are likely to do so only infrequently and for a short period only Equipme...

Страница 25: ...mp achieves its specified ultimate vacuum is the pump s leak rate low enough to en sure that no explosive atmospheres will occur in the interior of the equip ment After any intervention at the vacuum...

Страница 26: ...4 to 140 50 to 104 10 to 60 10 to 40 Permissible relative atmospheric moisture during operation no condensation 30 to 85 Maximum permissible installation altitude above mean sea level ft m 6500 2000 R...

Страница 27: ...thread G 1 2 A weighted emission sound pressure level uncertainty KpA 3 dB A dB A 56 50 Dimensions L x W x H approx in mm 21 0 x 10 2 x 16 5 533 x 260 x 420 Weight approx lbs kg 61 9 28 1 Type PC 301...

Страница 28: ...e with gas ballast Torr mbar 2 2 3 Maximum permissible range of supply voltage 10 Attention Observe specifications of rating plate 200 230 V 50 60 Hz Maximum rated motor current at 200 230 V 50 60 Hz...

Страница 29: ...mping potentially explosive atmospheres 50 F to 104 F 10 C to 40 C Operating condition Inlet pressure Permitted range of gas temperatures at inlet Continuous operation 75 Torr 100 mbar high gas load 5...

Страница 30: ...adjustment and at constant temperature 0 75 Torr 1 mbar Temperature coefficient 0 07 mbar K 0 05 Torr K Ambient temperature range operation 50 F to 104 F 10 C to 40 C Ambient temperature range storage...

Страница 31: ...reinforced Outlet hose nozzle at outlet PP Exhaust waste vapor condenser catchpot Borosilicate glass Overpressure safety relief device Silicone rubber PTFE foil Outlet of exhaust waste vapor condense...

Страница 32: ...alkane PP Polypropylene PPS Polyphenylene sulfide PTFE Polytetrafluoroethylene Position Component 1 Inlet 2 Outlet 3 ON OFF switch 4 Mains connection 5 Fuse holder 6 Pump rating plate 7 Fan 8 Handle 9...

Страница 33: ...page 33 of 152 ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO 9 8 1 2 8 17 16 17 5 3 6 4 7 7 PC 3016 NT VARIO PC 3012 NT VARIO PC 3010 NT VARIO 9 8 10 14 13 15 1 2 8 11 12 17 16...

Страница 34: ...page 34 of 152 1 8 2 9 18 PC 3012 NT VARIO EK Peltronic 12 11 16 8 17 3 4...

Страница 35: ...t valve serial interface RS 232 C Rear side CVC 3000 rating plate Depending on technical version the connections of the VACUU BUS ca bles are equipped with a nib When connecting the VACUU BUS connecti...

Страница 36: ...turvallisuustiedot Sigurnosne napomene za vakuumske ure aje A v kuum k sz l kekkel kapcsolatos biztons gi tudnival k Istruzioni di sicurezza per apparecchi a vuoto Vakuumin s rangos saugos informacija...

Страница 37: ...pipes Note Flexible elements will compress or flatten when evacuated if not designed for use under vacuum Hose connections at the pump inlet must al ways be gas tight Use a suitable adapter to connect...

Страница 38: ...of the pump especially if the gas ballast valve is open If this constitutes a potential source of danger take appropri ate safety measures When assembling ensure vacuum tightness After as sembly check...

Страница 39: ...e g into a fume hood Never block the gas outlet The exhaust line must always be free of obstructions no back pressure to ensure an unimpeded discharge of gas The cross section of the outlet tubing mus...

Страница 40: ...hattering in case of break age or implosion Assemble the catchpot at the exhaust waste vapor condenser using a joint clip over pressure safety relief device Check the overpressure safety relief device...

Страница 41: ...ge Only install the optional coolant valve in the supply line of the exhaust waste vapor con denser Note Install the hoses of the cooling system in a way to avoid the flow dripping of con densed water...

Страница 42: ...ic emission condenser and observe the instructions contained in that manual NOTICE Catchpot The catchpot is coated with a protective layer to protect against shattering in case of break age or implosi...

Страница 43: ...ion for PTFE tube I D 3 8 O D 5 16 10 8 mm via hose or PTFE tubing to the vacuum application The cross section of the tubing should be as large as possible Inside a vacuum system where evaporation occ...

Страница 44: ...the pressure transducer if necessary See section Cleaning the pressure transducer pg 82 NOTICE Connect the CVC 3000 controller to the VACUU BUS cable of the NT VARIO pump Attention Do not apply off a...

Страница 45: ...Accessories Spare parts pg 93 The vacuum controller CVC 3000 controls VACUUBRAND diaphragm pumps NT VARIO and optional coolant and venting valves Connected components e g venting valve external press...

Страница 46: ...is adequate especial ly if the ambient temperature is elevated max 104 F 40 C If the pump is installed at an altitude of more than 6500 ft 2000 m above mean sea lev el check compatibility with applica...

Страница 47: ...in the winding Note Only manual reset is possible Press the START STOP key at the controller to confirm the error message Switch off the pump and disconnect from the power source Identify and eliminat...

Страница 48: ...last This constitutes a risk of significant damage to equipment and or facilities a risk of per sonal injury or even loss of life Make sure that air gas intake through the gas ballast valve can never...

Страница 49: ...eases the solvent recovery rate at the exhaust waste vapor condenser In case of condensation In case of condensation Check the liquid lev el in the catchpots during operation Check the liquid level in...

Страница 50: ...run at atmo spheric pressure for a few minutes Has the pump been exposed to media which may damage the pump materials or form deposits Check and clean pump heads if necessary Has the pressure transdu...

Страница 51: ...preselected function and the pressure reading Attention Do not assemble or remove plug connections off axis Orient the plug correctly before inserting To connect additional components use VACUU BUS Y...

Страница 52: ...nge of value and to reach further parameters or to leave the set up menu Pump down Vac control Auto mode only with NT VARIO pump Program VACUULAN Configuration Selected function displayed in the upper...

Страница 53: ...NT VARIO pump Pump down continuous pumping Process runtime only if process control is running 5 In line valve switched on Level sensor activated catchpots need to be emptied Peltronic emission conden...

Страница 54: ...re chosen appropriately it is possible to start imme diately if similar operating conditions are desired The controller features five functions and one configuration menu see section Menu guide Each o...

Страница 55: ...ntrol pump based on time and pressure preselections or Auto mode Coolant valve Venting valve VACUULAN Use continuous speed control to manage NT VARIO pumps based on pressure and time preselections Coo...

Страница 56: ...c Back Function Pump down Vac control Auto mode Program VACUULAN Configuration Back MODE Menu guide Configuration Adjustment 743 Torr RS 232 Sensors Display Autostart Off Defaults Cancel Back VACUULAN...

Страница 57: ...ration Off Graphic Back Function Pump down Vac control Auto mode Program VACUULAN Configuration Back Program Edit Open 0 Store 0 Delay Off Graphic Back 1013 2 Auto mode mbar Auto mode Sensitivity norm...

Страница 58: ...Minimum is adjustable in a range of 1 795 Torr 1 1060 mbar or can be set to Off A preset Duration process time has no effect if the process is stopped due to a preset Minimum before Duration is reache...

Страница 59: ...key The controller switches to Vac control function the current vacuum is used as set value Pressing MODE key again switches to Auto mode function The controller adapts the boiling pressure starting f...

Страница 60: ...of 1 100 or can be set to HI The selection HI recommended provides the optimum pumping speed of the pump and therefore an optimum ultimate vacuum Maximum An upper pressure limit can be preselected The...

Страница 61: ...ction knob twice to return to the standard display Temporarily switching from Vac control to Auto mode while pro cess control is running Press MODE key The controller switches to Auto mode and adapts...

Страница 62: ...vacuum can be fine adjusted by turning the selection knob while process is running Turn the selection knob A full turn causes a change of the set vacuum of 9 Torr 12 mbar Turning the knob one detent...

Страница 63: ...meters determined during the pro cess Only in case of very sensitive processes is it advisable to reduce the maximum speed Minimum If the vacuum value reaches Minimum the process is stopped Use Minimu...

Страница 64: ...DE key The controller switches to Vac control The cur rent pressure value is used and held as new set point The preset function of the controller does not change due to this tem porary switching When...

Страница 65: ...fast as possible to the preset vacuum level As soon as the vacuum level is reached the time meter starts running Auto Auto indicates that the system will search for a boiling point automatically and w...

Страница 66: ...r and the step number in that program along with the vacuum setting the actual current pressure and the actual runtime are displayed across the top The timeline in the diagram adapts automatically to...

Страница 67: ...anges in the boiling point The following step starts either 1 once the cumulative process time reaches the set limit 1 hour 60 minutes even if the preset pressure 2 Torr mbar hPa has not been reached...

Страница 68: ...in the range of 1 795 Torr 1 1060 mbar Switch on the higher switching value If the pressure exceeds this pressure pumping down starts again The Switch on pressure is adjustable in the range of 2 795 T...

Страница 69: ...00 VACUULAN Set vacuum 19 Torr Switch on 150 Torr Delay 15 min Graphic Back 00 00 00 When selecting Graphic the display shows a pressure vs time curve The timeline in the diagram adapts automatically...

Страница 70: ...vent Start process by pressing START STOP key alternatively Select Vac control function Set Set vacuum to a value which does not lead to evaporation of the solvent If necessary set value for Speed hig...

Страница 71: ...ommended Select Auto mode Start process by pressing START STOP key The Auto mode allows a fully automatic distillation even if the boiling vacuum is unknown In case of solvent mixtures the vacuum is r...

Страница 72: ...tion knob Pressing MODE key a second time switches to Auto mode causing the vacuum level to be automatically adapted to changes of the boiling pressure alternatively Select Vac control function Set a...

Страница 73: ...also know as a rough ing pump or backing pump for a high vacuum pump e g turbo molec ular with high fore vacuum tolerance Use Pump down function with Speed set to HI or Use Vac control function with...

Страница 74: ...t is possible Torr is displayed RS 232 Configuration of the interface setting of parameters and com mands see section Interface Baud rate can be set to 19200 9600 4800 or 2400 parity on 8 N 1 7 O 1 or...

Страница 75: ...rovide appropriate safety measures If necessary the user has to check prior to starting the process if the option Autostart is enabled Defaults If Defaults is set to Load the controller is reset to fa...

Страница 76: ...nce Speed controlled chemistry diaphragm pumps and chemistry pumping units Instructions for use Technology for Vacuum Systems ME 16C NT VARIO MV 10C NT VARIO MD 12C NT VARIO PC 3010 NT VARIO PC 3012 N...

Страница 77: ...ps 26 Gas inlet temperatures 29 Wetted parts 31 Abbreviations 32 Pump parts 32 Use and operation 36 Installation 36 Vacuum connection inlet 37 Separator AK at the inlet 38 Connecting the outlet 39 Exh...

Страница 78: ...Setting of the interface 84 Read commands CVC 2000 85 Write commands CVC 2000 86 Read commands CVC 3000 88 Write commands CVC 3000 90 Accessories Spare parts 93 Troubleshooting 96 Replacing the device...

Страница 79: ...Torr 20 to 700 mbar no adjustment is possible Torr is displayed NOTICE Adjustment at atmospheric pressure An adjustment at atmospheric pressure is only possible if the pressure is higher than 525 Torr...

Страница 80: ...adjustment under vacuum to a pres sure 0 1 Torr mbar adjustment to a pre cisely known reference pressure within the range of 0 15 Torr 20 mbar is possible Evacuate the measurement connection of the CV...

Страница 81: ...r D K 15154 01 The DAkkS is signatory to the multilateral agreements of the European cooperation for Accreditation EA and of the International Laboratory Ac creditation Cooperation ILAC for the mutual...

Страница 82: ...me Observe all regulations concerning usage and disposal of sol vents Drain the solvent and dispose of in accordance with regulations Repeat cleaning if necessary Rinse the measurement chamber several...

Страница 83: ...ctrically isolated from the measuring circuit The controller is fully operable via the serial interface Measuring results preselections and the status of the controller can be read at any time The fac...

Страница 84: ...rol ler to Remote off in menu configuration Switch off the controller Then switch the controller back on and press the selection knob within 2s A maximum of ten commands per second is possible Read co...

Страница 85: ...aloperation mode pressure transducer last command to interface incorrect IN_STAT status of process control 0XXX 1XXX X0XX X1XX XX00 XX01 XX02 XX03 XX10 XX11 XX20 XX21 XX22 XX23 XX30 XX31 XX32 XX33 coo...

Страница 86: ...lection see respective function for parameter range OUT_SP_V set vacuum with venting XXXX unit mbar Torr hPa according to pre selection see respective function for parameter range OUT_SP_2 set frequen...

Страница 87: ...cted the user has to ensure that no dangerous status of the system can occur due to the change of the mode of operation and must take appropriate safety precautions especially if selecting remote oper...

Страница 88: ...X XXXXXXXXX0XXXXXX XXXXXXXXX1XXXXXX XXXXXXXXXX0XXXXX XXXXXXXXXX1XXXXX XXXXXXXXXXX0XXXX XXXXXXXXXXX1XXXX XXXXXXXXXXXX0XXX XXXXXXXXXXXX1XXX XXXXXXXXXXXXXyXX XXXXXXXXXXXXXXyX XXXXXXXXXXXXXXX0 XXXXXXXXXXX...

Страница 89: ...XXXXXX X1XXXXXXX XX0XXXXXX XX1XXXXXX XXX0XXXXX XXX1XXXXX XXXX0XXXX XXXX1XXXX XXXXX0XXX XXXXX1XXX XXXXXX0XX XXXXXX1XX XXXXXXX0X XXXXXXX1X XXXXXXXX0 XXXXXXXX1 no fault at pump fault at pump no fault at...

Страница 90: ...0 9 venting valve in program step y 0 9 IN_SP_P4y Step 0 1 no Step in program step y 0 9 Step in program step y 0 9 IN_SP_P5y Auto 0 1 no Auto in program step y 0 9 Auto in program step y 0 9 IN_PV_S...

Страница 91: ...9 OUT_SP_P1y time XX XX XX XX XX XX total runtime until program step y 0 9 or time for program step y 0 9 additive OUT_SP_P2y pressure XXXX pressure at program step y 0 9 unit according to preselecti...

Страница 92: ...ion interferes with a locally operated active process With command ECHO 1 a return value can be activated at write com mands A return value is only given if the command is performed cor rectly After b...

Страница 93: ...able RS 232C 9 pin Sub D 637837 Installation set CVC 3000 clips and screws 636593 Level sensor control of liquid level in catchpots 699908 VACUU BUS Digital I O Module 636228 e g fault indicator remot...

Страница 94: ...e DN 15 mm PP 662808 Adapter small flange KF DN 25 2x connection for PTFE tube I D 3 8 O D 5 16 10 8 mm PP incl centring ring with FEP coated seal ring 667052 PTFE hose KF DN 25 1000mm 686033 Vacuum v...

Страница 95: ...om Vacuum distribution The VACUU LAN modules allow process ori ented flexible and cost effective connections according to your requirements One vacuum pump can support several workstations Con tact VA...

Страница 96: ...Check current draw of the connected devices Short circuit at connect ed valves Replace valves Short circuit at the RS 232 plug Check plug and cable Other than above men tioned causes Contact local di...

Страница 97: ...valve or use new valve or reconfigure with out valve Warning triangle and pump symbol are flashing six blips NT VARIO pump and VMS Vacuum Man agement System con nected Remove VMS Restart controller F...

Страница 98: ...its ultimate vacuum or usual pumping speed Centring ring at small flange connection not correctly positioned or leak in the pipeline or vacuum system Check pump directly connect CVC 3000 di rectly at...

Страница 99: ...ping disc loose Perform maintenance Other than above men tioned causes Contact local distributor Pump seized Contact local distributor A service manual with exploded view drawings spare parts list and...

Страница 100: ...ns two fuses of the same type Replace the defective fuse by a fuse of the same type see Technical data pg 26 Insert the fuse holder into the housing until it snaps Switch off the pump Disconnect the e...

Страница 101: ...ors to discharge Ensure that the pump cannot be operated accidentally Note The pump might be contaminated with the pro cess chemicals that have been pumped during opera tion Ensure that the pump is de...

Страница 102: ...ing circumstances it may be efficient to check and clean the pump heads on a regular basis In normal use the lifetime of the diaphragms and valves is typically 15 000 operating hours Prevent internal...

Страница 103: ...3 of 152 Tools required metric Torx driver T10 T20 3 4 5 mm wide Allen key 2 5 mm wide slotted screwdriver Flat pliers Phillips screwdriver size 1 2 Diaphragm key width 66 mm Disassembling the pump ho...

Страница 104: ...page 104 of 152 2 3 size 1 2x 4...

Страница 105: ...page 105 of 152 6 5 7 4 4x...

Страница 106: ...page 106 of 152 9 8 1 2 2 5 mm 2 5 mm 10 ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO...

Страница 107: ...page 107 of 152 11 9A 2 5 mm Emission condenser Peltronic Emission condenser Peltronic 4 2x 10A...

Страница 108: ...page 108 of 152 12 Emission condenser Peltronic 4 4x 11A 13 4 2x...

Страница 109: ...page 109 of 152 15 14 4 4x Don t loosen this screw 15A 16...

Страница 110: ...page 110 of 152 16 17 5 2x 15A 1 2 3 1 4 1 4 3 2x 5...

Страница 111: ...page 111 of 152 19 20 18 5 2x...

Страница 112: ...Position Component 1 Clamping bracket 2 Disc spring 3 Valve head 4 O rings 5 Valves 6 Head cover 7 Diaphragm clamping disc with square head screw 8 Diaphragm Position Component 9 Diaphragm support dis...

Страница 113: ...page 113 of 152 21 2 5 mm Replacing the diaphragms 22 23 696867 696839 Clean 5 8x...

Страница 114: ...page 114 of 152 24 25 26 1 2...

Страница 115: ...page 115 of 152 27 3 28 29 Pay attention to number of washers...

Страница 116: ...page 116 of 152 30 31 32 1 2 Pay attention to number of washers 4 4 ft lbf 6 Nm It is recommended to use a torque wrench Attach torque wrench to diaphragm key hexagonal bolt 6 mm wide...

Страница 117: ...page 117 of 152 33 34 35 Replacing the valves 5 8x Screw in diagonally at first slightly then tighten 8 9 ft lbf 12 Nm T20 4x...

Страница 118: ...page 118 of 152 36 37 38 Clean...

Страница 119: ...page 119 of 152 39 40 41 IN IN EX EX 696867 696839 4x...

Страница 120: ...page 120 of 152 42 43 44 IN EX T20 4x 2 2 ft lbf 3 Nm...

Страница 121: ...page 121 of 152 45 46 47 Maintain all pump heads in the same way...

Страница 122: ...page 122 of 152 48A 48B 48C ME 16C NT VARIO PC 3016 NT VARIO MD 12C NT VARIO PC 3012 NT VARIO MV 10C NT VARIO PC 3010 NT VARIO...

Страница 123: ...page 123 of 152 48D ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO PC 3016 NT VARIO PC 3012 NT VARIO PC 3010 NT VARIO...

Страница 124: ...f 152 1B ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO size 2 2x Replacing the valve at the distributor not ME 16C NT VARIO PC 3016 NT VARIO 1 2 5 mm 1A 2 5 mm ME 16C NT VARIO MD 12C NT VARIO MV 10C...

Страница 125: ...page 125 of 152 2 size 2 2x 3 4A Version A valve 24 4 mm...

Страница 126: ...page 126 of 152 5A 696839 24 4 mm 26 mm 4B 5B 696839 37 mm 40 mm Version B valve 37 mm...

Страница 127: ...page 127 of 152 6 7 size 2 2x 7A ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO size 2 2x...

Страница 128: ...page 128 of 152 8 9 Do not operate the pump without pump housing Danger due to freely rotating fan Risk of overheating due to missing cooling air guide...

Страница 129: ...page 129 of 152 49 Assembling the pump housing 50 51 5 2x 8 9 ft lbf 12 Nm...

Страница 130: ...page 130 of 152 52 53 54 5 2x 8 9 ft lbf 12 Nm...

Страница 131: ...page 131 of 152 55 55A 1 2 3 3 2x 55A 56...

Страница 132: ...page 132 of 152 56 4 4x 3 7 ft lbf 5 Nm 58 4 4x 3 7 ft lbf 5 Nm 57 4 2x 3 7 ft lbf 5 Nm...

Страница 133: ...page 133 of 152 59 60 61...

Страница 134: ...page 134 of 152 Emission condenser Peltronic 59A 60A Emission condenser Peltronic 4 2x Emission condenser Peltronic 61A...

Страница 135: ...page 135 of 152 62 63 4 4x 3 7 ft lbf 5 Nm 64...

Страница 136: ...page 136 of 152 65 66 67 size 1 2x...

Страница 137: ...page 137 of 152 68 69...

Страница 138: ...this does not change after the break in period Check hose connectors at pump heads for leaks If necessary recheck valve seats and pump chambers Checking the ultimate vacuum After any intervention at...

Страница 139: ...page 139 of 152 Replacing the overpressure safety relief device at the exhaust waste vapor condenser 1 2 T20 4x size 1 4x 3...

Страница 140: ...page 140 of 152 4 638821 638821 5 6...

Страница 141: ...page 141 of 152 7 T20 4x size 1 4x 8...

Страница 142: ...ired Also decontaminated devices must not returned to VACUUBRAND due to a residual risk The same conditions apply to on site work No repair maintenance return or calibration is possi ble unless the co...

Страница 143: ...ce parts for cosmetic reasons at your request and at your expense Before returning the device Pack the device properly if necessary please order origi nal packaging materials at your costs Mark the pa...

Страница 144: ...ormal wear and tear of wearing parts such as diaphragms seals valves vanes condensers oil and the breakage of glass or ceramic parts for the consequences of chemical electrochemical or electrical infl...

Страница 145: ...for reason of appearance repaint and replacement at customer s expense yes no 12 Legally binding declaration We assure for the returned device that all substances which have been in contact with the...

Страница 146: ...e rating plate Voir plaque signal tique Angewandte harmonisierte Normen Harmonized standards applied Normes harmonis es utilis es DIN EN 12100 2011 DIN EN 61010 1 201 IEC 61010 1 2010 Ed 3 DIN EN 1012...

Страница 147: ...l Protection Use Period EPUP EPUP defines the period in years during which the hazardous substances contained in electrical and electronic products will not leak or mutate under normal operating condi...

Страница 148: ...disclosures in the above table the subassemblies are not intentionally manufactured or formulated with lead Pb mercury Hg cadmium Cd hexavalent chromium Cr VI polybrominated biphenyls PBB and polybrom...

Страница 149: ...page 149 of 152...

Страница 150: ...page 150 of 152...

Страница 151: ...page 151 of 152...

Страница 152: ...efore strictly the users responsibil ity to very carefully check the application of these data to their specific requirements No claims arising from the information provided in this lit erature will c...

Отзывы: