page 50 of 80
Accessories
Check valve (flapper valve)
......................................................................
20639683
(Simultaneous operation of two systems at different pressure levels,
stainless steel/FFKM, leak rate < 1.6*10-3 Torr*cfm
for pressure differences > 375 Torr (500 mbar))
Level sensor for catchpots.........................................................................
20699908
Vacuum hose (caoutchouc) I.D. 3/8” (10 mm ID) .....................................
20686002
Silencer for hose nozzle 3/8” (DN 10 mm) ...............................................
20636588
Upgrade possibilities for NT vacuum systems:
Upgrade kit SYNCHRO ...........................................................................
20699920
to two inlets (valve block; replaces distribution head)
Adapter G 1/4 thread to PTFE tubing*, .....................................................
20677060
for inlet at valve block (SYNCHRO)
Small flange KF DN 16
.............................................................................
20662593
for assembly at inlet of valve block (SYNCHRO)
Seal ring for small flange KF DN 16 (20662593)
......................................
23120565
Hose nozzle for tubing I.D. 1/4” / 3/8” (DN 6/10 mm), ...............................
20642470
for inlet at valve block (SYNCHRO)
Modification kit for small flange KF DN 16
.................................................
20699939
at inlet of distribution head
Hose nozzle for tubing I.D. 1/4” / 3/8” (DN 6/10 mm), ...............................
20636635
for inlet at distribution head
Elbow piece (90°) for PTFE tubing* ...........................................................
20637873
for assembly at inlet of distribution head
Adapter for gas ballast connection ............................................................
20636193
Via small flange KF DN 16
Blind flange (C1)
.......................................................................................
20677136
for assembly at valve block or distribution head
Attention
: Dust-laden gases, deposits and condensed solvent vapor can restrict
air flow out the silencer. The resultant back pressure can lead to damage of pump
bearings, diaphragms, and valves. Under those conditions, a silencer must not be
used.
Vacuum gauge DVR 2pro .........................
20682906
Содержание MD 4C NT
Страница 32: ...page 32 of 80 ME 4C NT 1 5 4 7 6 8 2 ME 2C NT 1 5 4 7 6 8 2 ...
Страница 34: ...page 34 of 80 ME 8C NT MD 4C NT 1 5 3 4 7 6 2 8 8 5 4 7 6 1 2 ...
Страница 57: ...page 57 of 80 Fittings and tubing of the different pump models ME 4C NT MZ 2C NT ME 8C NT MD 4C NT ...
Страница 73: ...page 73 of 80 Declarations and certificates ...
Страница 74: ...page 74 of 80 ...
Страница 78: ...page 78 of 80 ...
Страница 79: ...page 79 of 80 ...