background image

7.4 Gallon Thermal 

Sous Vide Circulator

09/2021

Thank you for purchasing this VACPAK-IT equipment. Before operating the equipment,

please carefully read the following operating and safety instructions.

ITEM

DESCRIPTION

VOLTAGE

WATTAGE

SVC280

7.4 Gallon Thermal Sous Vide Circulator

120 V

1800 W

Содержание SVC280

Страница 1: ...21 Thank you for purchasing this VACPAK IT equipment Before operating the equipment please carefully read the following operating and safety instructions ITEM DESCRIPTION VOLTAGE WATTAGE SVC280 7 4 Gallon Thermal Sous Vide Circulator 120 V 1800 W ...

Страница 2: ...2 Safety Instructions 3 Features 4 Specifications 4 Control Panel View and Functions 5 Operating Instructions 6 Maintenance Guide 6 Troubleshooting 7 Warranty 8 More from VACPAK IT 9 Table of Contents ...

Страница 3: ...eat 9 DO NOT operate equipment in public areas and or around children 10 DO NOT operate if equipment has been damaged or is malfunctioning in any way 11 Only use this model for intended purpose 12 DO NOT use this model to heat oil grease or any other liquid besides water 13 DO NOT put your hands directly in the water 14 The machine may still be hot to the touch right after use 15 To prevent electr...

Страница 4: ...PANEL LID MAIN BODY HANDLE Model SVC280 Dimensions 22 4 x16 9 x10 9 568x429x277mm Voltage 120V Frequency 60Hz Power 1800W Max Temperature 203 F 95 C Time Setting 5 min 99 hours Display Accuracy 1 1 F Capacity 7 4 gal Output 1 2 gal min ...

Страница 5: ...Fahrenheit hold both the and arrows 3 Press one time to confirm the settings you have chosen If is pressed and no selection has been made the mode will be exited after the LEDs flash 10 times A long press of will display the set time and temperature in turns 1 After setting the desired temperature and time press to start the machine 2 Press again to stop the machine and return to standby mode 1 11...

Страница 6: ...enance Guide 1 Open the lid on the thermal circulator and fill the container with water until it reaches a level between the MAX and MIN fill lines on the inside of the machine 2 Connect the unit to the appropriate power supply then turn on the power switch 3 On the display set the necessary time and temperature refer to Control Panel View and Functions Press the start button to start heating the ...

Страница 7: ...heating time Water goes on heating after the set temperature is reached Temperature sensor is invalid The circulator does not rotate Take the machine to be repaired by a specialist E01 Low water Check if the water level is lower than the MIN water line Check and ensure the filter is not stuck Check if the water level switch and relative circuit is OK require technicians to check and repair E02 The...

Страница 8: ... to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and damage due to improper maintenance wear and tear misuse abuse vandalism or Act of God Any action for breach of this warranty must be commenced within 1 year of the date on which the breach occurred No modification of this warranty or waiver of its terms shall be eff...

Страница 9: ...9 More from V acpak it CHAMBER VACUUM PACKAGING MACHINES VACUUM PACKAGING BAGS ...

Отзывы: