4.2.3 Considerations for Control Wiring
Control wiring refers to the wires connected to the control terminal strip. Select control wiring as
follows:
1. Shielded wire is recommended to prevent electrical noise interference from causing improper operation
or nuisance tripping.
2. Use only UL recognized wire.
3. Wire voltage rating must be at least 300 V for 230 Vac systems. It must be at least 600 V for 460 or
575 Vac systems.
See
below for a summary of control wiring specifications.
Table 4-1: X5 Power Terminal Wiring Specifications
Frame Size
Specifications
Torque Nom.
Torque Max.
Max. Wire Size
Strip Length
Size 0
12 in-lbs
13 in-lbs
12-24 AWG
5/16” (0.3125”)
Size 1
16 in-lbs
18 in-lbs
8-18 AWG
5/16” (0.3125”)
Size 2
30 in-lbs
6-8 AWG
3/8” (0.38”)
Size 3
35 in-lbs
3 AWG
Size 4
65 in-lbs
3/0 AWG
Size 5
132 in-lbs
400 MCM
Table 4-2: User-Supplied Terminal Cross-Reference
Wire Size
Manufacturer
Manufacturer’s P/N
Manufacturer
Manufacturer’s P/N
3 AWG
T&B
54107
2 AWG
T&B
54107
1 AWG
T&B
54108
1/0 AWG
T&B
54152-TB
Burndy
YA25-L6BOX
2/0 AWG
T&B
54157
Burndy
YA26-L5BOX
3/0 AWG
T&B
54162-TB
Burndy
YA27-LBOX
4/0 AWG
Burndy
YA28-LBOX
250 MCM
Burndy
YA29-LBOX
300 MCM
Burndy
YA30-L
350 MCM
Burndy
YA31-L
400 MCM
Burndy
YA32-L1
Table 4-3: X5 Control Wiring Specifications
X5 Size / Models
Specifications
All Sizes / Models
4.4 in-lbs maximum torque
12-24 awg wire
9/32” strip length