8.

 

Remove the power cable cover 

and detach the grounding rack 

9.

 

Take the IP54 cable cover and 

connect the fan power cable to 
connector marked with 'FAN' 

10.

 

Use the attached screws to fix 

the IP54 cable cover with fan and 
the grounding rack. 

 

11.

 

Open the cover of the FR6 

power unit. 

12.

 

Connect the other end of the fan 

cable extension to the +24V terminal 
on the power board. 

13.

 

Push the other end of the 

extension cable through the cover, 
fix the cover and connect finally the 
fan power cable to its extension. 

 

14.

 

Fix the IP54 cable entry flange 

placing it with the old grommets 
down and the new ones up. Fix the 
lower side with screws from the old 
flange. 

15.

 

Fit the IP54 cover in its place. 

Keypad end first, then cable end. 

16.

 

Use the attached screws (#5) to 

fix the IP54 cover on the upper end 
of the converter. 

 

17a.

 

Then fix the screws (4x10) on 
the lower end of the converter. 
Note the different fixing places 
for different frames. 

17b.

 

Tighten the four screws on the 
IP54 cover to fix it in its place. 

18.

 

Attach the warning sticker 

(#6/ #7) on the IP54 cover. 

 

FR4 

FR5 

FR6

FR5

FR4

FR4

FR5

FR6

FR6 

FR6

FR4

FR5

FR4 

FR5 

FR4

FR5

FR4

FR5

Содержание NX

Страница 1: ...vacon nx ac drives ip54 kit installation manual ...

Страница 2: ......

Страница 3: ... Vacon IP54 kit contents 3 2 1 FR4 Type designation code NXIP54FR4 3 2 2 FR5 Type designation code NXIP54FR5 4 2 3 FR6 Type designation code NXIP54FR6 4 3 Installation 5 3 1 Installation instructions 1 5 3 2 Information sticker 7 ...

Страница 4: ...the IP54 frequency converter enclosure provides protection against dust and water sprayed from all directions Limited ingress of both is permitted 2 VACON IP54 KIT CONTENTS The contents of the IP54 kits for different frames are shown in the following pictures 2 1 FR4 Type designation code NXIP54FR4 Figure 1 Contents of IP54 kit for FR4 1 IP54 enclosure for FR4 2 IP54 cable cover with fan 3 Cable e...

Страница 5: ...with fan 3 Cable entry flange with rubber grommets 4 Cable extension for fan 5 Rubber sealings 6 Screws 4x10 7 Warning sticker 2 3 FR6 Type designation code NXIP54FR6 Figure 3 Contents of IP54 kit for FR6 1 IP54 enclosure for FR5 2 IP54 lid with fan 3 Cable entry flange with rubber grommets 4 Cable extension for fan 5 Rubber sealings 6 Screws 4x10 7 Warning sticker 1 5 1 2 3 6 7 5 2 3 5 6 7 7 4 4 ...

Страница 6: ...ngles exist the step is applicable to all frames 3 1 Installation instructions 1 1 Detach the fan 2a Insert the plastic sealing 4 2b Insert the rubber sealing 3 Carefully re install the fan en suring that the connector clip fits accurately DO NOT SLAM DO NOT FORCE 4a Remove the plastic cover of the frequency converter and open the small lid on the power unit cover Leave the opening uncovered 4b Re...

Страница 7: ...the cover fix the cover and connect finally the fan power cable to its extension 14 Fix the IP54 cable entry flange placing it with the old grommets down and the new ones up Fix the lower side with screws from the old flange 15 Fit the IP54 cover in its place Keypad end first then cable end 16 Use the attached screws 5 to fix the IP54 cover on the upper end of the converter 17a Then fix the screws...

Страница 8: ...P54 upgrade kit delivered by the factory includes a sticker shown below Please check IP54 Collar 1 and mark the installation date 2 on the sticker Finally attach the sticker on your drive Drive modified Option board NXOPT IP54 upgrade Collar in slot Date A B C D E EMC level modified H to T Tto H Date Date 1 2 ...

Страница 9: ......

Страница 10: ...Document ID Rev A Vacon Ltd Member of the Danfoss Group Runsorintie 7 65380 Vaasa Finland www danfoss com ...

Отзывы: