VACON CX
Modbus user’s manual
Page
21
________________________________________________________________________________________
________________________________________________________________________________________
Vacon Oy
Phone +358-201-2121
Fax: +358-201-212 205
7.5
Installation of CX211OPT in Vacon CXS drives
NOTE: The option boards on the pictures may not look exactly the same as the one you have purchased.
These instructions are, still, applicable.
A
Remove the control panel and the panel base.
B
Remove the fixing screw from the control
board and replace it with a stand sleeve (4).
C
Connect the power cable (5) to terminal X5 of
the control board. The power cable can also
be connected to terminal X6 if terminal X5 is
already reserved by the power cable from the
power board.
D
Remove the protective foil of the plastic board
and place the plastic board above the control
board. Be sure to place the plastic board
correctly so that the stand sleeve (4) comes
out through the hole on the board.
E
Place the board on the protective plastic
board (6) and connect the data cable (2) to
terminal X14 of the control board. The stand
sleeve should come out through the metal-
edged hole.
F
Secure the board on the stand sleeve with
the screw (3) attached.
4
5
6
4
X14
2
3